Highly Stable Industrial Ups Systems  EPO And Bypass Control , Large Uninterruptible Power Supply

Highly Stable Industrial Ups Systems EPO And Bypass Control , Large Uninterruptible Power Supply

  • High Light

    industrial uninterruptible power supply systems

    ,

    industrial ups systems

  • Input Voltage
    380/400/415VAC±20%
  • Input Frequency
    50/60HZ±5%
  • Bypass Rated Voltage
    220/230/240Vac Single-phase
  • Operation Temp.
    0ºC/ + 40ºC
  • Relative Humidity
    <95% Non Condensing
  • Color
    Light Gray (RAL 7035)
  • Place of Origin
    Shenzhen, China
  • Brand Name
    CONSNANT
  • Certification
    CE, ISO9001, ISO14001
  • Model Number
    CNI310
  • Minimum Order Quantity
    1
  • Price
    Negotiable
  • Packaging Details
    Export Standard Package
  • Delivery Time
    15-20 days after receiving 30% deposit
  • Payment Terms
    T/T, L/C, Western Union
  • Supply Ability
    1000 pieces per year

Highly Stable Industrial Ups Systems EPO And Bypass Control , Large Uninterruptible Power Supply

 

Highly Stable Industrial UPS Power Supply With EPO And Bypass Control 10-160KVA

 

 

High-reliability Design:

 

The CNI310 system is composed of power special-purpose UPS, DBW regulator cabinet, PDU series feeder cabinet. CONSNANT Company apply herself to the development of China’s electricity demands for power plants, substations, power distribution products are designed with online double conversion, zero conversion function. Main applications include electric power long distance, RTU, power carrier wave, power monitoring and so on. When the utility power is normal, single phase 220V(or three phase 380V.) After isolation, rectification and filtering through the inverter to provide a stable power supply to the load; if the input AC power is abnormal or power failure, the backup power system by the DC screen provide power through non-return diode inverter. When the DC screen occurs voltage shortage or power break, the static switch transfer to bypass for power supply; when the electricity is restored, the inverter automatically switches to utility power and provide power supply under inverter mode. If the inverter overload or fault and transfer power supply under bypass mode, also give a warning signal at the same time.

 

 

Features:

 

  • Adopt full digital control technology, intelligent detection and monitoring function
  • Digitally control the static switch with zero switch
  • Full isolation between input and output; DC UPS isolated with utility power completely
  • Super low output zero earth voltage
  • Cubical design with power standard (customization)
  • Multifunctional protection for overvoltage, under voltage, over current, short circuit and over temperature and so on.
  • Large-screen LCD monitor with Chinese and English operation interface; Ultralong 256 event record, user-friendly analysis and management to the situation of the power supply (touch screen optional)
  • Static bypass has a strong anti-overload capability
  • Bypass standard features: BackFeed protection; split bypass line

 

Mainly Application:

 

 

Petroleum, chemical industry, gas and power station and so on.

 

Why Choose Us?

 

  • We have experienced team for more ten years and high-tech equipment.
  • Our material is with CE and ISO certificate.
  • We can make product according to your requirements, such as logo,size, color, design.
  • We can offer you very competitive price.

 

 

Technical Index:

 

CNI310 10-100KVA
Model 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA
Capacity 8KW 12KW 16KW 24KW 32KW 48KW 64KW 80KW
Input
Rated voltage 380/400/415 Vac three
Voltage range ±20%
Frequency range 50/60HZ±5%
Power factor ≥0.8
Current harmonic distortion <5%with harmonic filter
Soft start 0-100% in 10”
Bypass Input
Rated voltage 220/230/240Vac single-phase
Permitted voltage range ±15%(selectable from ±10% to ±25% from front panel)
Rated frequency 50/60Hz
Permitted frequency range ±2%(selectable from ±1% to ±5% from front panel)
Batteries
Type Maintenance-free lead-acid VRLA AGM / GEL;NICd
Maximum recharge current(A) 0.2 X C10
DC Voltage 384VDC
AC ripple voltage <1%
Inverter output
Number of phase 1
Rated voltage(V) 230Vac single phase
Regulation of the output voltage 220~244Vac phase/neutral(from control panel)

Crest factor

(Ipeak/Irms)

3:1
Static stability ±1%
Dynamic stability ±5%
Frequncy 50/60Hz configurable
Overload 110% 125% 150% of the rated current for 5h/10'/1'
Frequency stability ±0.05% on mains failure;±2%(selectable from ±1% to ±5%)with mains supply present
System
Remote signaling Volt free contacts
Remote controls EPO and Bypass
Communication RS232 + remote contacts
Weight(KG)N.M 200 220 230 260 290 340 440
 

Highly Stable Industrial Ups Systems  EPO And Bypass Control , Large Uninterruptible Power Supply 0