High Power Density Modular UPS System 4 Units Max Parallel Same Cabinet Battery Sharing

High Power Density Modular UPS System 4 Units Max Parallel Same Cabinet Battery Sharing

  • Highlight

    redundant ups power supply

    ,

    commercial ups battery backup

  • Single System Maximum Power
    300KVA
  • Max. Parallel Unit
    4 Units
  • Bypass Overload Cap
    Full Load >0.99 Half Load>0.98
  • Application
    Backup Power
  • Output Capacity
    Long Term At 135% Rated Load, 150%1000% 100ms
  • Output Volt
    380/400V415VAC 3-phase 4-wire
  • Place of Origin
    Shenzhen, China
  • Brand Name
    CONSNANT
  • Certification
    CE, ISO9001, ISO14001
  • Model Number
    CNM330 -300K
  • Minimum Order Quantity
    1 Unit
  • Price
    Negotiable
  • Packaging Details
    Wooden Case
  • Delivery Time
    20days after receiving 30% deposit
  • Payment Terms
    T/T, L/C, Western Union
  • Supply Ability
    500 pieces per month

High Power Density Modular UPS System 4 Units Max Parallel Same Cabinet Battery Sharing

 

Sine Wave And PF = 1 Modular UPS System With Low Input THDI And Unity PF



Brief Information:

 


CNM330 series is modular online UPS for sensitive equipment. The single cabinet power rating covers from 30KVA to 300KVA which delivers the best of combination of reliability, hot-swappable and flexibility. With the latest IGBT three-level technology and DSP control, CNM330 achieves a high input power factor, low THDi Modular design with N+X redundancy and online hot swapping ,easy to expand the capacity Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance and reduced size
 

 

Advantages:

  • Support module parallel and hot- swap, good performance for enlarge capacity in field and manufactory, maintenance;
  • High output power factor is 1 for example(150KVA=150KW),high ability for output load. Rectifier and inverter using Three level technology, enhance the efficiency.
  • Using high reliability monitor platform, enhance monitor processing ability, One monitor monitoring and communication with 5 power module and 1 bypass module at the same time.
  • Battery sharing technology in the same cabinet

 

 

 

 

150KVA input THDi and PF with 400V rating voltage
  100% linear 100% non linear
THDi_A (%) 2.760 3.430
THDi_B (%) 2.830 2.800
THDi_C (%) 2.650 2.420
PF_A 0.9999 0.9999
PF_B 0.9999 0.9999
PF_C 0.9999 0.9999

 

 


Application:


Application IDC(Internet Data Center)

Computing center

ISP (Internet Service Provider )

Telecom , Finance, bank and securities , Tax

Hospital system , industrial automation

Precision equipment, etc.

 

 

 

Specication:

 

model CNM330
Input voltage 380V/400V/415V (South American 208V option ,derating use)
Input Frequency 50/60HZ
THDI THDI<3%
Power Factor Full load >0.99 half load>0.98
Battery voltage ±240VDC(default) 12V battery 30-40PCS can be choose
Bypass overload capacity

Long term at 135% rated load, 150%<load<180% 10min ,

Load>1000% 100ms

Output voltage 380/400V415VAC 3-phase 4-wire
Voltage Accuracy ±0.5% (balanced load) ±1% (unbalanced load)
Power factor 0.9 / 1
Overload capacity 110% 1H , 125% 10mins , 150% 1min , >150% 200ms
Communication ports RS232 , RS458 , Dry contact , SNMP card , EPO , generator port
System efficiency >96% at load above 50% , >95% at load above 25%

(Optional South America 208V must be derating use)