High Availability Hot Swapping Data Center Backup Power , Industrial Redundant Ups Power Supply

High Availability Hot Swapping Data Center Backup Power , Industrial Redundant Ups Power Supply

  • Highlight

    redundant ups power supply

    ,

    modular type ups

  • Inverter Output Voltage
    380/400/415VAC 3-phase 4-wire
  • Output Voltage Accuracy
    ±0.5% ( Balanced Load ); ±1% ( Unbalanced Load )
  • Output Cap. Type
    Large Type
  • Application
    Data Center, Hospital, Precision Equipment, ISP, IDC
  • Equipment Mode
    Centralized Model
  • Output Current Crest Ratio
    3:1
  • Place of Origin
    Shenzhen, China
  • Brand Name
    CONSNANT
  • Certification
    CE, ISO9001, ISO14001
  • Model Number
    CNM330 -300K
  • Minimum Order Quantity
    1 Unit
  • Price
    Negotiable
  • Packaging Details
    Wooden case
  • Delivery Time
    20days after receiving 30% deposit
  • Payment Terms
    T/T, L/C, Western Union
  • Supply Ability
    500 pices per month

High Availability Hot Swapping Data Center Backup Power , Industrial Redundant Ups Power Supply

Hot Swapping Modular UPS System With Low THDi N + X Redundancy Design

 

 

 

High Availability Configuration Structure
 

  1. Static switch module: System standard configuration module. Adopts SCR and AC contactor in parallel. High reliability, strong overload ability: 1000% for 1 min. Transfer time is less than 1ms. Have strong self-detect, inter-lock and full-protection function.
  2. Power Module: Freedom choice of capacity configuration according demand, easy to expand; Online double-conversion design to ensure the output quality; Each module has independent digital intelligent control; Each module can work independently; Each module has a separate charging system; All modules can be hot-swappable, easy for online maintenance; Each UPS module provide 4.5KW charge capacity, equivalent to 10 to 12A
  3. Rich Management Interface: Advanced battery management, data recorder
  4. Advanced self-diagnosis:Inverter and rectifier circuit working condition monitoring, battery capacity and status detection, equipment working environment temperature testing, ease of maintenance and management of equipment, fan of fault detection(can replace the fan without power)

 
Application:

 


Application IDC(Internet Data Center)
Computing center
ISP (Internet Service Provider )
Telecom , Finance, bank and securities , Tax
Hospital system , industrial automation
Precision equipment, etc.


 

 

Technical Specifications:

 

 

Model CNM330 20-300KVA
Capacity 20-300KVA
Main Input
Input Voltage 380V/400V/415V
Input Frequency Range 50/60Hz
Power Factor Full load>0.99 ,Half load >0.98
THDi THDi<3%
Input Power Soft-start Function 5-30s settable
Input Voltage Ranges 228V-476V;-20%~25% at Full load ; linear derating at -25% ~- 40%; can take 70% load at -40%
Frequency Range 40-70HZ
Battery
Battery Voltage ±240VDC(Default),12V Battery 30~40pcs can be choose
Charge Voltage Accuracy ±1%
Bypass
Bypass Input Voltage 380/400/415VAC 3-phase 4-wire
Voltage Range Default value is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , other ranges can be set via software
Overload Capacity Long term at 135% rated load ,150%<load<180% more than 10 min,
load>1000% 100ms
Output
Inverter Output Voltage 380/400/415VAC 3-phase 4-wire
Voltage Accuracy ±0.5% ( balanced load ) , ±1% ( unbalanced load )
THDV THDV<1% (linear load) , THDV<3% (nonlinear load)
Power Factor 0.9
Three Phase Angle Accuracy 120°± 0.5°
Current Crest Ratio 3:1
Overload Capacity 110%1h,125%10mins,150%1mins,>150%200ms
Transfer Time 0ms,15ms (Eco Mode)
System
Frequency 50Hz/60Hz (Settable)
Mains Synchronization Range ±2Hz(Default value), adjustable with step of 0.5Hz within range of +/- 0.5Hz - 3Hz
Protection Level IP20
Communication Ports RS232,RS485,dry contact, SNMP card, EPO, generator port
System efficiency >96% at load above 50%, >95% at load above 25%
Operation Temperature 0-40ºC
Storage Temperature -25ºC~70ºC ( without battery)
Humidity 0-95% (no-condensing)
Noise(dB) 55-62dB,Adjusted with load
Weight module:PM20 20KVA power module : 30KG
module:PM30 30KVA power module : 35KG
module:PM40 40KVA power module : 40KG
Dimension (W x D x H)mm 3 module cabinet 600X900X1135
5 module cabinet(5 battery cabinet option) 600X1100X2070/
6 module cabinet 600X900X1535
10 module cabinet 900X900X2080
power module 440X650X132(3U)(10KVA/20KVA/30KVA)


(Optional South America 208V must be derating use)