Electricity Industrial UPS Uninterrupted Power Supply High Power 10 - 100KVA
Product Snapshot:
Model: 10-100 KVA
Nominal voltage: 380/400/415VAC
Nominal frequency: 50Hz/60Hz
Output power factor: 0.8
Application:
Petroleum, chemical industry, gas and power station and so on.
Technical Specification:
CND310 10KVA-100KVA | ||||||||||||||
Model (KVA) | 10 | 15 | 20 | 30 | 40 | 50 | 60 | 80 | 100 | |||||
Rating capacity(KW) | 8 | 12 | 16 | 24 | 32 | 40 | 48 | 64 | 80 | |||||
Rating voltage | 220V(one-phase) /380V(three phase) | |||||||||||||
AC input | ||||||||||||||
Voltage range | ±25% | |||||||||||||
Frequency range | 50,60Hz±10% | |||||||||||||
Soft start | 0-100% in 5” | |||||||||||||
Power factor | 0.95(with input filter) | |||||||||||||
Bypass input | ||||||||||||||
Permitted voltage range | ±15% | |||||||||||||
Frequency range | 50/60Hz±5% | |||||||||||||
Output | ||||||||||||||
Voltage accuracy | 220V±1%(steady load) 220V±3%( fluctuating load) | |||||||||||||
Permitted Frequency range | 50/60Hz±0.05Hz(powered by battery) | |||||||||||||
Power factor | 0.8 | |||||||||||||
THD | Linearload<2%, non linear load<4% | |||||||||||||
Dynamic transients | <5% | |||||||||||||
Current crest ratio | 3:1 | |||||||||||||
Overload capacity | Normal in 110% load, 125% for 10min | |||||||||||||
Efficiency | Double switch:94%, ECO:98% | |||||||||||||
DC | ||||||||||||||
Battery voltage | 220V | |||||||||||||
Cutoff voltage | 185V | |||||||||||||
Maximum discharge current | 36A | 55A | 73A | 109A | 145A | 181A | 218A | 291A | 364A | |||||
Penal display | ||||||||||||||
LCD | Chinese/English UPS status, operation instruction input voltage, output voltage, current, frequency, battery voltage, value of charge and discharge current, accident display, warning | |||||||||||||
Environment | ||||||||||||||
Temperature | 0ºC-40 ºC | |||||||||||||
Humidity | 0-95%(no condensing) | |||||||||||||
Storage temperature | -25 ºC—55 ºC | |||||||||||||
Altitude | <1500m |
Key features:
Control system:
It adopts microprocessor bus control technology, three core processor controlling rectification, inversion and parallel connection respectively, to ensure the real-time control of the rectifier, inverter and static switch and the coordination of every power part, characterized by increased control of aging, higher reliability, enhance of the efficiency of the whole UPS system and the output technical parameters are better than that of the device with same capacity.
Rectifier:
6 pulse or 12 pulse fully controlled bridge (6 or 12 SCR) compose rectifier. Its function is to input AC 3880V to DC220V or so by rectification. “slope” start (soft start) is the control feature, which means output voltage of the rectifier increase from 0V to 220V within 10 second and has no impact on the power grid.
Inverter:
SPWM(sinusoidal pulse width modulation) , formed by 6 IBGT high power tubes, is composed of full-bridge-control. Its function is to transform DC voltage into sinusoidal AC voltage, boosting by the special (△/Y) zero phase shift zigzag type isolation transformer and become AC220V as load required. In addition, the transformer can eliminate like triple harmonics current that are reflected by non linear load from computer. Control features is the adoption of the “slow-down gate voltage” protection technology, greatly reducing disturbance of shutoff of the inverter (inverter and static switch shift mutually ), enhancing the overload capacity of the whole UPS system, which make the capability of anti-short circuit and anti overload of UPS far superior to the ordinary UPS, especially the anti shot circuit is unmatched by similar devices.
Large Capacity of Overload of the UPS Inverter
110% load --60'
125% load --10'
150% load --1'
200% single phase load --30"
Good Capacity of Resistance to Output Short Circuit Current Limiting and Period Load Impact
Advantages:
290% rated current -- 5": Even though a output short circuit or an overload occurs because of user’s improper operation, the output current of UPS can still be limited to a controllable extent instead of exceedingly increasing, consequently laying a good foundation for a long-term and reliable operation of UPS.
Static switch
Not sync automatically switch:
Optional bypass cabinet:
Isolating transformer and the bypass voltage regulation
Intelligent monitoring:
Working status and data of UPS are transmitted to DCS system in real-time via RS232/RS485, passive contact and power transmitter, which finally realize Intelligent monitoring.
Unique option: