AC / DC Off Grid Solar Inverter Dry Contact 1 - 12kw Hybrid Singlt Phase
Features:
1. AC/Solar Charging Off Grid Hybrid Inverter.
2. LED/LCD display, Enhanced functions setting via LCD, Man-machine intelligent design
3. Built-in 40A/60A optional MPPT solar charger controller.
4. LCD shows the solar capacity.
5. 5 stages adjustable AC charging current. AC charging also can be closed
6. AC/DC priority modes can be set.
7. Generator restart signal. (Dry contact)
8. 3 times peak power. Strong loading capacity.
9. Overload, output short-circuit protection.
CNS110 Series Technical Specifications:
| Battery Inverter Mode Specifications: | |||
| Output | Output Voltage | Sine wave | |
Rated Output | LV:1-6KW | HV:1KW-12KW | |
| Power Factor | 0.9~1.0 | ||
Nominal Output | LV:120Vac±10% rms | HV:230 Vac±10% rms | |
Nominal Output | 60Hz±0.3Hz | ||
| DC Voltage | Nominal DC | 12VDC/24VDC/48VDC | |
| DC Voltage Range | 10-15.5Vdc for 12V battery | ||
| 20-31.0 Vdc for 24V battery | |||
| 40-62.0 Vdc for 48V battery | |||
| Low Battery Alarm | 10.5Vdc±0.3Vdc for 12V Battery | ||
| 21.0 Vdc±0.6Vdc for24V Battery | |||
| 42.0 Vdc±1.2Vdc for 48V Battery | |||
Low DC | 10.0Vdc±0.3Vdc for 12V Battery | ||
| 20.0Vdc±0.6Vdc for 24V Battery | |||
| 40.0Vdc±1.2Vdc for 48V Battery | |||
| High DC input alarm&fault | 16Vdc±0.3Vdc for 12V Battery | ||
| 32Vdc±0.6Vdc for 24V Battery | |||
| 64Vdc±1.2Vdc for 48V Battery | |||
| High DC input recorvery | 15.5Vdc±0.3Vdc for 12V Battery | ||
| 31.0Vdc±0.6Vdc for 24V Battery | |||
| 62.0Vdc±1.2Vdc for 48V Battery | |||
| AC Charger | Nominal Charge Current | 20A/35A/50A/70A/90A(5satges adjustable charging current) | |
| Charge Current Regulation | ±5Adc | ||
| Over Charge protection | Bat.V≧15.5VDC for 12V battery | ||
| Bat.V≧31.0VDC for 24V battery | |||
| Bat.V≧62.0VDC for48V battery | |||
| Beeps 0.5s every 1s& fault after 60S | |||
| Algorithm | |||
| Three stage:Boost CC(Constant current stage) →Boost CV(Constant voltage stage) →Float(constant voltage stage) | |||
| Solar Charger | Rated Charge Current | 40A | 60A |
| Rated Charge Battery Voltage Type | 12V/24V/48V | 12V/24V | |
| Max PV open Circuit array voltage | 12V for 40Vdc | ||
| 24V for 40Vdc | |||
| 48V for 110Vdc | |||
| Charger Mode | MPPT | ||
| PV Low Voltage Re-connect | PV≧Bat.V=3V | ||
| PV Low Voltage Disconnect | PV≦Bat.V | ||
| Efficiency | Efficiency | ≧97% | |
| Efficiency(Battery Mode) | ≧85% | ||
| Efficiency(Line Mode) | >98% | ||
| Transfer Time | AC to DC | 20ms(Max) | |
| DC to AC | 15ms(Max) | ||
| System parameter | Over-load Protection | 110%<load<150%, beeps 0.5s every 1s, and fault after 60s off the output, | |
| Surge rating(10s) | 1:3(VA) | ||
| Power Saver | Load≦25W(enabled on “P/S auto” setting of Remote comtro;) | ||
| Protections | Low battery, over charging, overload, over temp | ||
| Indicatoers | LED+LCD Display | ||
| General Specifications | Operation Temperature Range | 0℃ to 40℃ | |
| Strorage Temperature | -15℃~60℃ | ||
| Operation Humidity | 5% to 95%(non-condensing) | ||
| Audible Noise | 60dB max | ||
| Cooling | Forced air, Variable speed fan | ||
| Dimension(L*W*H) | 1-3KW: 526*423*260mm | ||
| Net Weight(Kg) | 1KW:21.5Kg; | 1.5KW:23.5Kg | |
| 3KW:30.5Kg | 4KW:32Kg | ||
| 5KW:36.5Kg | 6KW:40.5Kg | ||
| 7KW:43.5Kg | 8KW:50Kg | ||
| 10KW:57.5Kg | 12KW:60Kg | ||
![]()