| Model |
HT4830S80-145 |
HT4840S80-145 |
HT4850S80-145 |
HT4825U80-145 |
HT4830U80-145 |
HT4835U80-145 |
| Mains mode |
| Rated input voltage |
220/230Vac |
110/120Vac |
| Input voltage range |
(170Vac~280Vac) ±2%
(90Vac-280Vac)±2% |
(90Vac~140Vac) ±2% |
| Frequency |
50Hz/ 60Hz (automatic detection) |
| Frequency range |
47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~ 65±0.3Hz (60Hz); |
| Overload/short circuit protection |
Circuit breaker |
| Efficiency |
>95% |
| Conversion time |
10ms (typical) |
| (bypass and inverter) |
| AC backflow protection |
Yes |
| Maximum bypass overload current |
40A |
| Inverter mode |
| Output voltage waveform |
Pure sine wave |
| Rated output power (VA) |
3000(2600/2700
/3000) |
4000(3480/360
3800/4000) |
5000(4350/4500
/4800/5000) |
2500(2000/2180
/2290) |
3000(2500/2600
/2750) |
3500(2900/3000
/3200) |
| Rated output power (W) |
3000(2600/2700
/3000) |
4000(3480/360
3800/4000) |
5000(4350/4500
/4800/5000) |
2500(2000/2180
/2290) |
3000(2500/2600
/2750) |
3500(2900/3000
/3200) |
| Power factor |
1 |
| Rated output voltage (Vac) |
230Vac(200/208/220/240Vac Settable) |
120Vac(100/105/110Vac Settable) |
| Output voltage error |
±5% |
| Output frequency range (Hz) |
50Hz ± 0.3Hz
60Hz ± 0.3Hz |
| Efficiency |
>92% |
>91% |
| Overload protection |
(102%<load<125%) ±10%: Report error and turn off output after 5 minutes;
(125%<load<150%) ±10%: Report error and turn off output after 10 seconds;
Load>150% ±10%: Report error and turn off output after 5 seconds; |
(102%<load<110%) ±10%: Report error and turn off output after 5 minutes;
(110%<load<125%) ±10%: Report error and turn off output after 10 seconds;
Load>125% ±10%: Report error and turn off output after 5 seconds; |
| Peak power |
6000VA |
8000VA |
10000VA |
4000VA |
4500VA |
5000VA |
| Loaded motor capacity |
2HP |
3HP |
4HP |
1HP |
2HP |
2HP |
| Output short circuit protection |
Circuit breaker |
| Bypass circuit breaker specification |
63A |
| Rated battery input voltage |
48V (minimum starting voltage 44V) |
| Battery voltage range |
40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set) |
| Eco mode |
Load ≤ 50W |
| AC charging |
| Battery type |
Lead acid or lithium battery |
| Maximum charge current |
0-60A |
0-40A |
Charge
current error |
± 5Adc |
| Charge voltage range |
40 – 58Vdc |
40 – 60Vdc |
| Short circuit protection |
Circuit breaker |
| Circuit breaker specification |
(AC IN) 63A/(BAT) 125A |
| Overcharge protection |
Alarm and turn off charging in 1 minute. |
| PC charge |
| Maximum PV open circuit voltage |
145Vdc |
| PV operating voltage range |
60-145Vdc |
| MPPT voltage range |
60-115Vdc |
| Battery voltage range |
40-60Vdc |
| Maximum output power |
4200W |
| PV charge current range (settable) |
0-80A |
| Charge short circuit protection |
BAT circuit breaker and fuse |
| Wiring protection |
Reverse polarity protection |
| Hybrid charging Max charger current specifications (AC charger+PV charger) |
| Max charger current(can be set) |
0-140A |
0-120A |
| Certified specification |
| Specification certification |
CE(EN62109) |
| EMC certification level |
EN61000, C2 |
| Operating temperature range |
-15°C to 55°C |
| Storage temperature range |
-25°C ~ 60°C |
| RH range |
5% to 95% (conformal coating protection) |
| Noise |
≤60dB |
| Heat dissipation |
Forced air cooling, adjustable air speed |
| Communicat ion interface |
USB/RS485 (WiFi/GPRS)/Dry Node Control |
| Dimensions (L*W*D) |
482*425*133mm |
| Weight (kg) |
13.3 |