Model |
HT4830S80-145 |
HT4840S80-145 |
HT4850S80-145 |
HT4825U80-145 |
HT4830U80-145 |
HT4835U80-145 |
Mains mode |
Rated input voltage |
220/230Vac |
110/120Vac |
Input voltage range |
(170Vac~280Vac) ±2%
(90Vac-280Vac)±2% |
(90Vac~140Vac) ±2% |
Frequency |
50Hz/ 60Hz (automatic detection) |
Frequency range |
47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~ 65±0.3Hz (60Hz); |
Overload/short circuit protection |
Circuit breaker |
Efficiency |
>95% |
Conversion time |
10ms (typical) |
(bypass and inverter) |
AC backflow protection |
Yes |
Maximum bypass overload current |
40A |
Inverter mode |
Output voltage waveform |
Pure sine wave |
Rated output power (VA) |
3000(2600/2700
/3000) |
4000(3480/360
3800/4000) |
5000(4350/4500
/4800/5000) |
2500(2000/2180
/2290) |
3000(2500/2600
/2750) |
3500(2900/3000
/3200) |
Rated output power (W) |
3000(2600/2700
/3000) |
4000(3480/360
3800/4000) |
5000(4350/4500
/4800/5000) |
2500(2000/2180
/2290) |
3000(2500/2600
/2750) |
3500(2900/3000
/3200) |
Power factor |
1 |
Rated output voltage (Vac) |
230Vac(200/208/220/240Vac Settable) |
120Vac(100/105/110Vac Settable) |
Output voltage error |
±5% |
Output frequency range (Hz) |
50Hz ± 0.3Hz
60Hz ± 0.3Hz |
Efficiency |
>92% |
>91% |
Overload protection |
(102%<load<125%) ±10%: Report error and turn off output after 5 minutes;
(125%<load<150%) ±10%: Report error and turn off output after 10 seconds;
Load>150% ±10%: Report error and turn off output after 5 seconds; |
(102%<load<110%) ±10%: Report error and turn off output after 5 minutes;
(110%<load<125%) ±10%: Report error and turn off output after 10 seconds;
Load>125% ±10%: Report error and turn off output after 5 seconds; |
Peak power |
6000VA |
8000VA |
10000VA |
4000VA |
4500VA |
5000VA |
Loaded motor capacity |
2HP |
3HP |
4HP |
1HP |
2HP |
2HP |
Output short circuit protection |
Circuit breaker |
Bypass circuit breaker specification |
63A |
Rated battery input voltage |
48V (minimum starting voltage 44V) |
Battery voltage range |
40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set) |
Eco mode |
Load ≤ 50W |
AC charging |
Battery type |
Lead acid or lithium battery |
Maximum charge current |
0-60A |
0-40A |
Charge
current error |
± 5Adc |
Charge voltage range |
40 – 58Vdc |
40 – 60Vdc |
Short circuit protection |
Circuit breaker |
Circuit breaker specification |
(AC IN) 63A/(BAT) 125A |
Overcharge protection |
Alarm and turn off charging in 1 minute. |
PC charge |
Maximum PV open circuit voltage |
145Vdc |
PV operating voltage range |
60-145Vdc |
MPPT voltage range |
60-115Vdc |
Battery voltage range |
40-60Vdc |
Maximum output power |
4200W |
PV charge current range (settable) |
0-80A |
Charge short circuit protection |
BAT circuit breaker and fuse |
Wiring protection |
Reverse polarity protection |
Hybrid charging Max charger current specifications (AC charger+PV charger) |
Max charger current(can be set) |
0-140A |
0-120A |
Certified specification |
Specification certification |
CE(EN62109) |
EMC certification level |
EN61000, C2 |
Operating temperature range |
-15°C to 55°C |
Storage temperature range |
-25°C ~ 60°C |
RH range |
5% to 95% (conformal coating protection) |
Noise |
≤60dB |
Heat dissipation |
Forced air cooling, adjustable air speed |
Communicat ion interface |
USB/RS485 (WiFi/GPRS)/Dry Node Control |
Dimensions (L*W*D) |
482*425*133mm |
Weight (kg) |
13.3 |