Output PF 0.8 / 0.9 Rack Mount Power Supply Online UPS High Frequency
Nominal voltage: 208/220/230/240VAC
Nominal frequency: 50/60Hz
Output Power Factor: 0.8/0.9
Features:
1) LCD display, large blue interface in English, user-friendly(Panel Display: UPS status, input/output voltage and frequency, battery voltage, capacity, load temperature, history recods, adjust voltage, ECO mode)
2) Rack-Tower convertible
3) With ECO can be highly efficient energy-saving, reducing user costs
4) Double-conversion online design, so that the output of the frequency UPS tracking, lock-in voltage regulator,
filter noise low distortion, without interfering with the pure sine wave power supply fluctuations.
5) Advanced Digital Signal Processing (DSP) microprocessor technology to ensure the consistency and reliability
of UPS.
6) With battery hot-swapping function
Application:
Network, date center
CNH110RT 1-10KVA | |||||||||||
Model | 1K | 1KS | 2K | 2KS | 3K | 3KS | 6KS | 10KS | |||
Capacity | 1KVA/800W | 2KVA/1600W | 3KVA/2400W | 6KVA/4800W | 10KVA/8KW | ||||||
Nominal Voltage | 220/230/240VAC Single phase 2 wire+G | ||||||||||
Nominal Frequency | 50/60Hz | ||||||||||
Input | |||||||||||
Voltage Range | 115~300VAC | 120~275VAC | |||||||||
Frequency Range | 50Hz: (46~54Hz); 60Hz: (56Hz~64Hz) | ||||||||||
Power Factor | >0.98 | 0.99 | |||||||||
Output | |||||||||||
Voltage Precision | 220/230/240×(1±2%)VAC | ||||||||||
Frequency Precision | 50/60Hz±0.05Hz | ||||||||||
Power Factor | 0.8 | 0.8/0.9(Optional) | |||||||||
Harmonic Distortion | Linear load <3% Non-linear<6% | ||||||||||
Overload Capacity |
Load>110% for 47s; |
105%<load≦125% for 60s; |
|||||||||
Current Crest Ratio | 3:1 | ||||||||||
Transfer time | 0ms(AC mode↔DC mode);(AC mode↔Bypass<4ms) | ||||||||||
Battery | |||||||||||
DC Voltage | 36VDC | 72VDC | 96VDC | 192VDC or 240VDC | |||||||
Recharge Time | 5hours to 90%(it means standard model which battery inside UPS) | ||||||||||
Charging Current | 1A | 4A/8A | 1A | 4A/8A | 1A | 4A/8A | 4A | ||||
Panel Display | |||||||||||
LCD Communication | UPS status, input/output voltage and frequency, battery voltage, capacity, load temperature, history recods, adjust voltage, ECO mode | ||||||||||
Communication Port | RS232, SNMP Card(Optional0, USB port(Optional) | ||||||||||
Working Environment | |||||||||||
Temperature | 0℃~40℃ | ||||||||||
Relative Humidity | 0~95%(Non-condensing) | ||||||||||
Storage Temperature | -25℃~55℃ | ||||||||||
Elevation | 1500m | ||||||||||
Noise Level | <45dB | <50dB | <50dB |
STANDARD:Conform to GB/IEC regulation: EMC:GB7260.2/IEC62040-2
-GB/17626.2~5/IEC61000-4-2~5
SAFETY:GB4943
Note:Peoduct specifications are subject to change without further notice.