CNG331 Series
Low Frequency Online UPS
Product snapshot:
Model: 120-800KVA
Nominal Voltage: 380/400/415VAC
Nominal frequency: 50/60Hz
Output Power Factor: 0.9
Parallel : maximum 6 pcs UPS
Indicated Language: 12 types(En. Ru. Sp. Fr...)
Efficiency Rate of Machine: ≧94% (≧98% in ECO Mode)
Specifications:
Model |
120KVA /108KW |
200KVA /180KW |
300KVA /270KW |
400KVA /360KW |
500KVA /450KW |
600KVA /540KW |
800KVA /720KW |
|||||||||||||
Rated input voltage | 380/400/415VAC 3-phase 4-wire | |||||||||||||||||||
Rated frequency | 50/60Hz | |||||||||||||||||||
Input parameters | ||||||||||||||||||||
Input voltage range | ±25%℃≤ | |||||||||||||||||||
Input frequency range | 45Hz~65Hz | |||||||||||||||||||
Input soft start function | 0-100% 5-300S settable | |||||||||||||||||||
Input power factor | >0.98(if harmonic filter is added) | |||||||||||||||||||
Input harmonic current(THDi) | <4.5%(if harmonic filter is added) | |||||||||||||||||||
bypass | ||||||||||||||||||||
Voltage range | -20%~+15% | |||||||||||||||||||
Frequency range | 50/60Hz±10% | |||||||||||||||||||
Output parameters | ||||||||||||||||||||
Output voltage | 380/400/415VAC 3-phase 4-wire | |||||||||||||||||||
Voltage stability | ±1%(steady status), ±3%(transient status) | |||||||||||||||||||
frequency | 50/60Hz | |||||||||||||||||||
Mains power synchronization window | ±5% | |||||||||||||||||||
Actually measured frequency accuracy(internal clock) | 50/60Hz±0.05Hz | |||||||||||||||||||
Output power factor | 0.9(output 90KW per 100KVA) | |||||||||||||||||||
Transient response time | <5ms | |||||||||||||||||||
Inverter overload capacity | At 0.9 power factor, 110% fori hour, 125% for 10 minutes and 150% for 60 seconds | |||||||||||||||||||
Short circuit current form inverter | 3ph 1.5ln for 5 seconds, iph 2.9ln for 5 seconds | |||||||||||||||||||
Maximum bypass capacity | 1000% for 100ms | |||||||||||||||||||
Phase shift characteristic |
With 100% balanced load : <1°; With 100% imbalanced load :<1° |
|||||||||||||||||||
Total harmonic distortion(THDV) |
100% linear load: <1%; 100% non-linear load: <3% |
|||||||||||||||||||
System efficiency(full load) | Up to 94%(inverter efficiency is up to 98%) | |||||||||||||||||||
Rectifier | ||||||||||||||||||||
Charger output voltage stability | 1% | |||||||||||||||||||
DC ripple voltage | ≤1% | |||||||||||||||||||
Safety | ||||||||||||||||||||
standard | Safety: IEC60950-1 IEC62040-1-1 UL1778 EMC IEC62040-2 CLASS C2 EN50091-2 CLASS A | |||||||||||||||||||
Design and Test IEC62040-3 | ||||||||||||||||||||
Physical parameters | ||||||||||||||||||||
Weight(kg) | 980 | 1420 | 1200 | 1750 | 1350 | 2000 | 1600 | 2200 | 2100 | 2750 | 3690 | 6390 | 7300 | |||||||
Dimension (W*D*H)mm |
900*855* 1900 |
1250*855* 1900 |
1640*855*1900 | 1250*855*1900 |
2280*855* 1900 |
2280*855*1900 | 2835*1000*1950 | 3988*1090*1950 |
Operating Teperature: 0~40℃
Storage temperature: -25℃~70℃(inverter efficiency is up to 98%)
Relative humidity: 0~95%(non-condensing)
Maximum operating height ≤elevation: 1000m, for elevation above 1000m, derate by 1% for every increase of 100m
Noise(1m): 58-68db
Protection level: IP20
Efficient-energy- saving+ Environmental-protection+innovation:
CNG331 series UPS for China’s top product, nominal capacity from 120KVA to 800KVA, dad application in key equipment for the power system protection, could provide high quality power, with high level of availability and scalability, and invest iminimize Total Cost of the Ownership(YCO)
Application:
Application mainly used in large IDC rooms, banks/securities settlement center, communication network management center, semi-production lines and large automation production with its control system. According to the special need of users was improved, used in large sports venues, conference room, theather, highway and railway tunnels metal halide lamp lighting system.
Key Features:
Excellent Electrical Performance:Online double transform structure, double DSP control technology
Super output overload capacity:"inversion state priority”thinking.
The typical overload capacity of UPS as follow:
110% rated load for one hour
125% rated load for ten minutes
150% rated load for one minute
With a strong anti-step of load and short circuit output capacity:
Three phase work, the output current is limited to 160% nominal output current, 5 seconds.
Single-phase operation, the output current is limited to 290% nominal output current, 5 second.
Superior ability with three phase unbalanced load:equipped with adaptive equilinrium adjustment circuit, when followed 100℃ unbalanced load(one-phase no-load, two phase full load, they can ensure that the three-phase phase voltage difference is less that 2C , and phase difference between the 120º±1º ranges. This indicator was higher than similar products of other companies.
N+X redundant design of auxiliary power supply:
CNG331 series UPS’s auxiliary power adopt Controlled circuit of auxiliary power for each provide reliable, stable power protection; 1+1 redundancy design, when one of the auxiliary power failure, can be continued by another auxiliary power supply. UPS continue to operate normally, while the LCD screen displays this warning message.
Unique battery protection:
1. Battery is isolation, safe and reliable;
2. Short circuit protection
3. In case of battery voltage causes the inverter lock, then switch off automatically to avoid battery discharge damage
4. Fitted with a remote emergency stop button, emergency stop button can be used remotely disconnect the switch; misuse protection
Easy maintenance of structure design:
Using user-friendly control panel modular inline graphic design, to ensure reliable connection between the plug plates, the connection is configurated with a connector locking mechanical”locking” device. Users simply open the cabinet door that can be observed a glance at the control panel of the UPS “self diagnosis” status monitor the work of the state. As a result, users can quickly access to nearly 70-90 species of fault alarm indication, and improve the maintainability of this UPS.
Efficiency, energy-saving, environmental protection design, efficiency of the machine is up to 94%:
Clean stable output waveform:
Output voltage curve 1% change in the sine envelope line digital pulse-width modulation with free frequency 250%, 200, 120%, 100%. roteting UPS SCR-based UPS Translator-based UPS CNG331 UPS Power Demands Non-liner load 100% . To ensure the non-linear load voltage voltage distortion ≤3% the min capacity of kinds of UPS need
High input power factor level, harmonic distortion cancellation: save cost of energy consumption, reduce power pollution
Core of high available configuration great parallel output features:
■There are frequency busbar and current busbar in parallel control system, they can control each UPS phase relation and flow equalize output feature. So the system not only ensure each UPS located in general UPS power supply can share load current, but also it can reduce the circulation maybe happened in parallel system to zero.
■ Moreover, because of sensitive circulation survey, it can survey the operative mode of UPS power supply system constantly and with high reliability (MTBF reach to 1 million hours), it is the top level in the similar type
High reliable UPS power solution
Unique option, one-step service:
Unique Option, One-stop Service
-SNMP card
-Parallel card
-Dry contact card
-C class lighting protection case
-Outlet option
-Bypass flow equalize inductance
-Battery temperature transmitter
- JBUS/MODBUS interface card
-UPS generator room signal adapter
-5 times harmonic or 11 times harmonic filter
Easy installation:
■layered freestanding obturator ventilation
■ Installed against the wall
■The favourable ventilation design
■Can pass in and out the cables from the top
Sales Service:
1. 2% spares together with shipment for urgent issue.
2. All of the necessary documents such as drawing, manaul etc.
3. We will provide the online service by mail
4. We also can desptach engineer to assist you solve the problem if necessary. But you are requested to pay for the cost of ticket, hotel etc.