High Frequency UPS Rack Mount Power Supply Battery Hot-swapping Function
Nominal voltage: 208/220/230/240VAC
Nominal frequency: 50/60Hz
Output Power factor: 0.8/0.9
Key Features:
1) Large blue LCD display interface in English, user-friendly
2) Rack-Tower convertible
3) With ECO (economic operation mode) can be highly efficient energy-saving, reduce user costs
4) Double-conversion online design, so that the output of the frequency UPS tracking, lock-in voltage regulator,
filter noise low distortion, without interfering with the pure sine wave power supply fluctuations.
5) Advanced Digital Signal Processing (DSP) microprocessor technology to ensure the consistency and reliability
of UPS.
6) With battery hot-swapping function
Rack-Tower convertible:
ECO(Economic Operation Mode)
Function:
Various choice and Installation Management:
DSP Full-digital Control:
Flexible Setting and change due to demand:
Intelligent Power Monitoring and Management Software WinPower 2003:
CNH110RT 1-10KVA | |||||||||||
Model | 1K | 1KS | 2K | 2KS | 3K | 3KS | 6KS | 10KS | |||
Capacity | 1KVA/800W | 2KVA/1600W | 3KVA/2400W | 6KVA/4800W | 10KVA/8KW | ||||||
Nominal Voltage | 220/230/240VAC Single phase 2 wire+G | ||||||||||
Nominal Frequency | 50/60Hz | ||||||||||
Input | |||||||||||
Voltage Range | 115~300VAC | 120~275VAC | |||||||||
Frequency Range | 50Hz: (46~54Hz); 60Hz: (56Hz~64Hz) | ||||||||||
Power Factor | >0.98 | 0.99 | |||||||||
Output | |||||||||||
Voltage Precision | 220/230/240×(1±2%)VAC | ||||||||||
Frequency Precision | 50/60Hz±0.05Hz | ||||||||||
Power Factor | 0.8 | 0.8/0.9(Optional) | |||||||||
Harmonic Distortion | Linear load <3% Non-linear<6% | ||||||||||
Overload Capacity | Load>110% for 47s; | 105%<load≦125% for 60s; | |||||||||
Current Crest Ratio | 3:1 | ||||||||||
Transfer time | 0ms(AC mode↔DC mode);(AC mode↔Bypass<4ms) | ||||||||||
Battery | |||||||||||
DC Voltage | 36VDC | 72VDC | 96VDC | 192VDC or 240VDC | |||||||
Recharge Time | 5hours to 90%(it means standard model which battery inside UPS) | ||||||||||
Charging Current | 1A | 4A/8A | 1A | 4A/8A | 1A | 4A/8A | 4A | ||||
Panel Display | |||||||||||
LCD Communication | UPS status, input/output voltage and frequency, battery voltage, capacity, load temperature, history recods, adjust voltage, ECO mode | ||||||||||
Communication Port | RS232, SNMP Card(Optional0, USB port(Optional) | ||||||||||
Working Environment | |||||||||||
Temperature | 0℃~40℃ | ||||||||||
Relative Humidity | 0~95%(Non-condensing) | ||||||||||
Storage Temperature | -25℃~55℃ | ||||||||||
Elevation | 1500m | ||||||||||
Noise Level | <45dB | <50dB | <50dB |
STANDARD:Conform to GB/IEC regulation: EMC:GB7260.2/IEC62040-2
-GB/17626.2~5/IEC61000-4-2~5
SAFETY:GB4943