100KVA 80 KW Low Frequency Online UPS High Intelligence Energy Saving For Data Centers

100KVA 80 KW Low Frequency Online UPS High Intelligence Energy Saving For Data Centers

  • High Light

    three phase online ups

    ,

    online double conversion ups

  • Input Frequency Range
    45-65Hz
  • Input Voltage
    80-300VAC ±20% Three Phase
  • Soft Start
    0-100% In10"
  • Battery Voltage
    384VDC
  • AC Ripple Voltage
    <1%
  • Crest Factor(Ipeak/Irms)
    3:1
  • Efficiency Smart Mode
    Up To 98%
  • Compliance
    Safety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive 2004/108/EC)
  • Place of Origin
    Shenzhen, China
  • Brand Name
    CONSNANT
  • Certification
    CE, ISO9001, ISO14001
  • Model Number
    CNG310
  • Minimum Order Quantity
    1
  • Price
    Negotiable
  • Packaging Details
    Export Standard Package
  • Delivery Time
    15-20 days after receiving the 30% deposit
  • Payment Terms
    T/T, L/C, Western Union
  • Supply Ability
    2000 Pieces per year

100KVA 80 KW Low Frequency Online UPS High Intelligence Energy Saving For Data Centers

 

CNG310 Series Low Frequency Online UPS 10-100KVA

 

 

 

Model:CNG310 10-100KVA(3Ph/1Ph)
Nominal Input Voltage: 380/400/415VAC
Output Power Factor:0.8

 

 

 

Application:
Servers,

Local area Network(LAN),

Data centers,

Telecommunications,

Electro-medical equipment

100KVA 80 KW Low Frequency Online UPS High Intelligence Energy Saving For Data Centers 0
High intelligence and reliable power supply:
CNG310 provides maximum protection for vital mission-critical networks, security applications (electro- medical)and industrial applications thanks to its outstanding mechanical and electrical design.
The load is powered continuously by the inverter with a filtered, stabilized and regulated sine wave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges.
The CNG310 uses on-line double conversion technology (VFI) with isolation transformer on the inverter output.
The CNG310 is supplied with Watch & Save 3000 software as standard and can be remotely monitored
using the Power Net Guard system from anywhere in the world. Additional battery extension packs allow the standard battery run time to be extended up to several hours.

Minimum impact on suppliers easy source:
Input current distortion <4% for the CNG310 with filter with sinusoidal absorption to remove the risk of resonance with other input supply users or phase shift capacitor sets. The absorbed current distortion is independent of input supply parameters such as impedance. This enable CNG310 to deliver maximum performance levels regardless of the installation environment. With these input features CNG310 can achieve significant savings in terms of sizing and power supply courcesiso-ation transformers and generators over less sophisticated power systems.

Maximum battery care:
Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.

Simple to install:
Capability to install the UPS into any distribution system(neutral not required on rectifier input);
Capability to separate the rectifier/bypass power networks and to power these from two separate sources, without Galvanic isolation (Necessary on UPS without an output transformer).

High reliability:
Extremely high short-circuit current to ensure compatibility with the most difficult transformer applications (lighting,drives and industrial processes) and an isolation transformer on the inverter output;
Full microprocessor control with no-break static and manual bypasses;
IGBT technology.

Other characteristics:
0.8 power factor make CNG310 suitable for powering ICT and Industrial loads;
High level diagnostics: event log with 128 messages, states,measurements and alarms - available from the built-in LCD with several languages;

Back feed protection:

To avoid energy feeding back into the mains supply cause a fault occur.

Maximum reliability and availability:
Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings.The UPS continue to work in parallel even if one of the interconnecting communication cables is disconnected (CLOOSED LOOP).

Low consumption level:
CNG310 can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.

Advance communication:
Compatible with TeleNetGuard for remote maintenance;
Advanced, multi-platform communication for all operation systems and network environments: Watch & Save 3000 monitoring and shut-down software included, with SNMP agent, for Windows 2008, Vista,2003, XP; Mac OS X,Linux, Novell and most popular Unix operating systems;

The UPS is supplied with a cable for direct connection to the PC(Plug and Play);
RS232 double Serial port;Installation slot for an Emergency Power Off (EPO) interface to allow the UPS to be switched off remotely in an emergency;
Generator interface: enables desynchronisation of the UPS output from a generator supply which may be subject to phase and frequency variations. The interface also enables more economic use of the battery charge.

Expandability:
The units can be connected in parallel up to 8 units to increase power availability or redundancy. The single module or the system can be expanded any time to suit power requirements without influencing the initial investment.

Technical parameter of CNG310 series:

 

Model power CNG310 10KVA
10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA
Capacity 8KW 12 KW 16 KW 24 KW 32 KW 48 KW 64 KW 80 KW
Input
Rated Voltage 80-300 Vac three-phase
Voltage Range ±20%
Frequency Range 45-65Hz
Power Factor >0.92with harmonic filter
Current Harmonic Distortion <5%with harmonic filter
Soft Start 0-100% in10"
Bypass Input
Rated Voltage 230Vac single-phase
Permitted Voltage Range ±15%(selectable from ±10% to ±25% from front panel)
Rated Frequency 50/60Hz
Permitted Frequency Range ±2%(selectable from ±1% to ±5% from front panel)
Standard Features BackFeed protection; split bypass line
Batteries
Type Maintenance-free lead-acid VRLA AGM / GEL;NICd
Battery Voltage 384VDC
Maximum Recharge Current(A) 0.2 X C10
AC Ripple Voltage <1%
Inverter Output
Number of Phases 1
Rated Voltage(V) 48Vac single-phase
Regulation of the Output Voltage 48Vac phase/neutral(from control panel)
Crest Factor(Ipeak/Irms) 3:1
Static Stability ±1%
Dynamic Stability ±5%
Frequency 50/60Hz configurable
Overload 110% 125% 150% of the rated current for 5h/10'/1'
Frequency Stability ±0.05% on mains failure
Remote Signaling Volt free contacts
Remote Controls EPO and Bypass
Communication RS232 + remote contacts
Operation Temperature 0ºC/ + 40ºC
Relative Humidity <95% non condensing
Color Light gray (RAL 7035)
Noise 54dBA at 1m 60dBA at 1m 65dBA at 1m
Protection Degree IP20
Efficiency Smart Mode up to 98%
Compliance Safety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive 2004/108/EC)