Shenzhen Consnant Technology Co., Ltd. 86-755-29772322 sales@consnant.com
220VAC 3KVA / 6KVA / 10KVA Distributed Power System Muninterruptible Power Supply Battery

220VAC 3KVA / 6KVA / 10KVA Distributed Power System Muninterruptible Power Supply Battery

  • High Light

    distributed power system 220VAC

    ,

    Muninterruptible distributed power system

    ,

    10KVA Muninterruptible Power Supply Battery

  • Application
    Data Center
  • Model
    DPS-1103A, DPS-1106A, DPS-1110A
  • Product Name
    Distribute Power Syste Muninterruptible Power Supply Battery
  • Power Factor
    ≧ 0.99
  • Nominal Capacity
    3KVA, 6KVA, 10KVA
  • Nominal Voltage
    220VAC
  • Output Voltage
    208/220/230/240VAC
  • Frequency
    50/60Hz
  • Working Temperature
    0 ℃ – 45 ℃
  • Optional
    Support SNMP CARD
  • Input Voltage Range
    176 – 250VAC (80-100% Load)
  • Place of Origin
    MADE IN CHINA
  • Brand Name
    Distribute Power System - DPS
  • Certification
    CE
  • Model Number
    DPS-1103A, DPS-1106A, DPS-1110A
  • Price
    Negotiable
  • Packaging Details
    Export Standard Package
  • Payment Terms
    T/T

220VAC 3KVA / 6KVA / 10KVA Distributed Power System Muninterruptible Power Supply Battery

Description

DPS series distributed power system

Performance characteristics

  • Intelligent detection, battery type optional, output shunt timing control

Intelligent detection of fan and capacitor running time

4 output shunts support timing control function

Battery type: lead-acid battery, lithium iron battery, ternary lithium battery and custom battery type

  • Reliable, intelligent and fast deployment

Modular design, rapid deployment on demand;

Simplify data center planning and design;

Compatible with T2/T3/T4 level in the same data center;

Intelligent detection of running time of fans and capacitors;

Dual 220VAC input, dual 220VAC output, can intelligently detect the power of other equipment (optional).

  • Effective use of space and load-bearing

The weight of the equipment is equivalent to that of the server, and the weight bearing only needs 500Kg/m2;

The deployment does not require independent distributed power system space and battery room, and the number of effective cabinets has increased by more than 40%;

☆Energy saving and emission reduction, cabinet-level energy management effectively combined with cloud computing

High efficiency power supply module, the efficiency of the whole series of products is as high as 94%;

Full lithium battery backup system, discharge efficiency up to more than 97%, life span up to 10 years;

Each output can be selected for time-sharing control. With the energy management system, it can achieve cabinet-level energy management and coordinate with cloud computing for scheduling;

☆Power supply host, modular design of lithium iron battery, hot swappable, easy installation and maintenance

The product is designed and produced in a modular manner. The power supply host and the iron-lithium battery are independent modules. They support hot swapping while ensuring that the power equipment does not lose power; small size, light weight, and can be completed by one person.

More convenient installation and simple maintenance

Reasonable design of heat dissipation and airflow control, good control of battery temperature;

The front part of the product is designed with heat dissipation holes and air ducts for the power supply heating device and the lithium battery, which can accurately control the temperature of the power supply and the lithium iron battery;

☆Conducive to the user’s demand for low “PUE” value

The distributed power supply mode divides the power consumption of the traditional large UPS into the cabinet and reduces the PUE value.

Application field

Power supply application scenarios such as distributed data centers, load-bearing limited data centers, phased deployment of data centers, rapid deployment of data centers, and integrated cabinets.

Power range: 1KVA – 10KVA (1PH/1PH)

 

Distribute Power System - DPS

Model: DPS-1103A, DPS-1106A, DPS-1110A
Nominal Capacity: 3KVA, 6KVA, 10KVA
Nominal Voltage: 220VAC
Power Factor: ≧ 0.99
Input Voltage Range: 176 – 250VAC (80-100% load)
Output Voltage: 208/220/230/240VAC
Frequency: 50/60HZ

Application field

  • Distributed Data center
  • Load-Bearing Data Centers
  • Staged deployment data centers
  • Rapid deployment data centers
  • Integrated cabinets

Technical parameter:

 

Model DPS-1103A DPS-1106A DPS-1110A
Capacity 3000VA / 2700W 6000VA / 5400W 10000VA / 9000W
Input
Input voltage 220VAC
Voltage Range 176-250Vac @ (80-100%) load
Frequency Range 46Hz – 54Hz @ 50Hz system; 56Hz – 64Hz @ 60Hz system
Power Factor ≧ 0.99
Output
Output voltage 208/220/230/240VAC
Voltage accuracy ±1% (battery mode)
Frequency range 46Hz – 54Hz @ 50Hz system; 56Hz – 64Hz @ 60Hz system (Synchronization range)
Frequency range 50Hz±0.1Hz or 60Hz±0.1Hz(battery mode)
Power factor ≧ 0.9
Crest factor 3:1 Max.
Harmonic distortion ≦2% @ 100% linear load; ≦3% @ 100% non-linear load
Transfer time 0 ms (AC mode); 0 ms (Inverter Mode); ﹤10 ms (Inverter ECO)
Run
Input and output 1 line input & 2 lines output or 2 lines input & 2 lines output
Efficiency
Inverter Mode ﹥ 94%
Battery
Battery type 192/230V lithium battery
Battery capacity 10AH/12AH/15AH/18AH/20AH/25AH/30AH
Appearance
Dimension

 

D × W × H (mm)

800 ×438 ×88(2U) Power Host

 

800 ×438 ×176(4U)/264(6U) include the lithium battery

Net Weight (kg) 28 (power host)
Environment
Storage temperature -25 ℃ – 55 ℃
Working temperature 0 ℃ – 45 ℃
Working altitude ﹤ 2000 m
Working humidity ﹤95% No condensation
Working noise ﹤55dB @ 1 meter distance
Management
Intelligent slot Support Window@2000/2003/XP/Vista/2008,Window @7/8, Linux and MAC
Optional Support SNMP CARD
 
  • The output efficiency will be reduce to 60% when CVCF mode;
  • The output power will be reduce to 90% when the output voltage set to 208VAC.

 

Model DPS-1101B DPS-1102B DPS-1103B
Capacity 1000VA / 800W 2000VA / 1600W 3000VA / 2100W
Input
Input voltage 220VAC
Voltage Range 176-250Vac
Frequency Range 46Hz – 54Hz @ 50Hz system; 56Hz – 64Hz @ 60Hz system
Power Factor ≧ 0.99
Output
Output voltage 208/220/230/240VAC
Voltage accuracy ±1% (battery mode)
Frequency range 46Hz – 54Hz @ 50Hz system; 56Hz – 64Hz @ 60Hz system (Synchronization range)
Frequency range 50Hz±0.1Hz or 60Hz±0.1Hz(battery mode)
Power factor ≧ 0.8 ≧ 0.7
Crest factor 3:1 Max.
Harmonic distortion ≦2% @ 100% linear load; ≦3% @ 100% non-linear load
Transfer time 6 ms (AC mode); 6 ms (Inverter Mode)
Run
Input and output 1 line input & 2 lines or 3 lines output
Efficiency
Inverter Mode ﹥ 91% (30-100%) load
Battery
Battery type 48V lithium battery
Battery capacity 10AH/15AH/20AH
Appearance
Dimension

 

D × W × H (mm)

800 ×438 ×44(1U) Power Host
Net Weight (kg) 8 (power host)
Environment
Storage temperature -25 ℃ – 55 ℃
Working temperature 0 ℃ – 45 ℃
Working altitude ﹤ 2000 m
Working humidity ﹤95% No condensation
Working noise ﹤55dB @ 1 meter distance
Management
Intelligent slot Support Window@2000/2003/XP/Vista/2008,Window @7/8, Linux and MAC
Optional Support SNMP CARD
  • The product is subject to the actual product, and the above specifications are subject to change without notice;
  • If the distributed power system is installed and used in an environment where the altitude exceeds 2000 meters, the output power should be calculated by 1% every 200 meters.
Model DPS-1103A DPS-1106A DPS-1110A
Capacity 3000VA / 2700W 6000VA / 5400W 10000VA/ 9000W
Input
Input voltage 220VAC
Voltage range 176-250Vac @ (80-100%) load
Frequency range 46Hz – 54Hz @ 50Hz system; 56Hz – 64Hz @ 60Hz system
Power factor ≧ 0.99
Output
Output voltage 208/220/230/240VAC
Voltage accuracy ±1% (battery mode)
Frequency range 46Hz – 54Hz @ 50Hz system; 56Hz – 64Hz @ 60Hz system (Synchronization range)
Frequency range 50Hz±0.1Hz or 60Hz±0.1Hz(battery mode)
Power factor ≧0.9
Crest factor 3:1 Max.
Harmonic distortion ≦2% @ 100% linear load; ≦3% @ 100% non-linear load
Transfer time 0ms(ACmode);0ms(InverterMode);﹤10ms(InverterECO)
Run
Input and output 1 line input&2 linesoutputor2 lines input&2 linesoutput
Efficiency
Inverter Mode > 94%
Battery
Battery type 192/230V lithium battery
Battery capacity 10AH/12AH/15AH/18AH/20AH/25AH/30AH
Appearance
Dimension D×W×H(mm) 800×438×88(2U) PowerHost;
800 ×438 ×176(4U)/264(6U) include the
lithium battery
Net weight(kg) 28 (power host)
Environment
Storage temperature -25 ℃- 55 ℃
Working temperature 0 ℃- 45 ℃
Working altitude ﹤2000 m
Working humidity ﹤95% No condensation
Working noise ﹤55dB @ 1 meter distance
Manegement
Intelligent slot Support Window@2000/2003/XP/Vista/2008,Window @7/8, Linux and MAC
Optional Support SNMP CARD