Shenzhen Consnant Technology Co., Ltd. 86-755-29772322 sales@consnant.com
Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage

Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage

  • High Light

    PV Grid Hybrid Solar Inverter

    ,

    Lithium Battery Hybrid Solar Inverter

    ,

    SPWM Hybrid Energy Storage Inverter

  • Color
    White
  • Frequency
    50Hz/ 60Hz (automatic Detection)
  • Battery Type
    Lead Acid Or Lithium Battery
  • Efficiency
    >95%
  • Communicat Ion Interface
    USB/RS485 (WiFi/GPRS)/Dry Node Control
  • Weight
    13.3KG
  • Place of Origin
    ShenZhen, China
  • Brand Name
    CONSNANT
  • Certification
    CE(EN62109); EN61000; C2
  • Model Number
    HT4830S80-145 | HT4840S80-145 | HT4850S80-145 | HT4825U80-145 | HT4830U80-145 | HT4835U80-145
  • Minimum Order Quantity
    20 Pieces
  • Price
    Negotiable
  • Packaging Details
    Export Standard Package
  • Delivery Time
    5-8 days for sample order, 15-21 days for large quantity
  • Payment Terms
    L/C, T/T, Western Union
  • Supply Ability
    1000 pieces per month

Lithium Battery PV Grid Hybrid Solar Inverter SPWM Energy Storage

Mutiple Mode Hybrid PV Energy Storage Grid Solar Inverter

 

Product Instruction:

 

     HT series is a new hybrid PV energy storage inverter controller integrating PV energy storage,mains charging

and storage and AC sine wave output. Using DSP control through advanced control algorithms, it comes with high

response speed, high reliability, high industrialization standard and other characteristics.

     Four charging modes are available: only PV, mains priority, PV priority, and hybrid charging by mains & PV;

     two output modes: inverter and mains are available to meet different application needs.

 

Key Feature:

1. Full digital voltage; current double closed loop control, combined with advanced SPWM technology to output

pure sine wave.
2. Two output modes and 4 charging modes are available for choice.
3. AdvancedMPPT technology with efficiency up to 99.9%.
4. LCD screen design, with 3 LED indicators, for dynamic display of system data and run status; ON/OFF rocker

switch controls AC output.
5. Power saving mode reduces no-load loss.
6. Intelligent variable speed fan ensures efficient heat dissipation, and thereby extends system life.
7. Double lithium battery activation modes: mains and PV, and supports lead-acid battery and lithium battery

access.
8. Multiple protections provide 360 ° all-round protection for the system. Complete protections include multi-electrical

appliance air switch short circuit protection, overvoltage and undervoltage protection, overload protection, back-flow

protection, etc.
9. Horizontal installation facilitates cabinet combination installation.
10. Lithium battery can be activated by both mains and PV panel.

 

Specification Reference:

Model HT4830S80-145 HT4840S80-145 HT4850S80-145 HT4825U80-145 HT4830U80-145 HT4835U80-145
Mains mode
Rated input voltage 220/230Vac 110/120Vac
Input voltage range (170Vac~280Vac) ±2%
(90Vac-280Vac)±2%
(90Vac~140Vac) ±2%
Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);
57±0.3Hz ~ 65±0.3Hz (60Hz);
Conversion time 10ms (typical)
(bypass and inverter)
Maximum bypass overload current 40A
Inverter mode
Output voltage waveform Pure sine wave
Rated output power (VA) 3000(2600/2700
/3000)
4000(3480/360
3800/4000)
5000(4350/4500
/4800/5000)
2500(2000/2180
/2290)
3000(2500/2600
/2750)
3500(2900/3000
/3200)
Rated output power (W) 3000(2600/2700
/3000)
4000(3480/360
3800/4000)
5000(4350/4500
/4800/5000)
2500(2000/2180
/2290)
3000(2500/2600
/2750)
3500(2900/3000
/3200)
Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable) 120Vac(100/105/110Vac Settable)
Output voltage error ±5%
Output frequency range (Hz) 50Hz ± 0.3Hz
60Hz ± 0.3Hz
Efficiency >92% >91%
Overload protection (102%<load<125%) ±10%: Report error and turn off output after 5 minutes;
(125%<load<150%) ±10%: Report error and turn off output after 10 seconds;
Load>150% ±10%: Report error and turn off output after 5 seconds;
(102%<load<110%) ±10%: Report error and turn off output after 5 minutes;
(110%<load<125%) ±10%: Report error and turn off output after 10 seconds;
Load>125% ±10%: Report error and turn off output after 5 seconds;
Peak power 6000VA 8000VA 10000VA 4000VA 4500VA 5000VA
Loaded motor capacity 2HP 3HP 4HP 1HP 2HP 2HP
Bypass circuit breaker specification 63A
Rated battery input voltage 48V (minimum starting voltage 44V)
Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery...LCD screen can be set)
Eco mode Load ””≤ 50W
AC charging
Maximum charge current 0-60A 0-40A
Charge
current error
± 5Adc
Charge voltage range 40 - 58Vdc 40 - 60Vdc
Circuit breaker specification (AC IN) 63A/(BAT) 125A
PC charge
Maximum PV open circuit voltage 145Vdc
PV operating voltage range 60-145Vdc
MPPT voltage range 60-115Vdc
Battery voltage range 40-60Vdc
Maximum output power 4200W
PV charge current range (settable) 0-80A
Charge short circuit protection BAT circuit breaker and fuse
Wiring protection Reverse polarity protection
Hybrid charging Max charger current specifications (AC charger+PV charger)
Max charger current(can be set) 0-140A 0-120A
Certified specification
Specification certification CE(EN62109)
EMC certification level EN61000, C2
Operating temperature range -15°C to 55°C
Storage temperature range -25°C ~ 60°C
RH range 5% to 95% (conformal coating protection)
Noise ≤”60dB
Heat dissipation Forced air cooling, adjustable air speed

 

 

Product Maintenance and Fault Handling:

No. Protections Remarks
1 PV current/power limiting protection When charging current or power of the PV array configured exceeds the PV rated, it will charge at the rated.
2 PV night reverse-current protection At night, the battery is prevented from discharging through the PV module because the battery voltage is greater than the voltage of PV module.
3 Mains input over voltage protection When the mains voltage exceeds 280V (230V model) or 140V (120V model), the mains charging will be stopped and switched to the inverter mode.
4 Mains input under
voltage protection
When the mains voltage is lower than 170V (230V model /UPS mode) or 90V (120V model or APL mode), the mains charging will be stopped and switched to the inverter mode.
5 Battery over voltage protection When the battery voltage reaches the overvoltage disconnection point, the PV and the mains will be automatically stopped to charge the battery to prevent the battery from being overcharged and damaged.

 

Faults Handling measures
No display on the screen Check if the battery air switch or the PV air switch has been closed;
if the switch is in the "ON" state; press any button on the screen to exit the screen sleep mode.
Battery overvoltage protection Measure if the battery voltage exceeds rated, and turn off the PV array air switch and Mains air switch.
Battery undervoltage protection Charge the battery until it returns to the low voltage disconnection recovery voltage.
Fan failure Check if the fan is not turning or blocked by foreign object.
Heat sink over temperature protection When the temperature of the device is cooled below the recovery temperature, normal charge and discharge control is resumed.
Bypass overload protection, inverter overload protection ① Reduce the use of power equipment;
② Restart the unit to resume load output.
Inverter short circuit protection ① Check the load connection carefully and clear the short-circuit fault points;
② Re-power up to resume load output.