Send Message
Shenzhen Consnant Technology Co., Ltd. 86-755-29772322 sales@consnant.com
Single Cabinet Automation Modular UPS System High Flexibility For Sensitive Equipment

Single Cabinet Automation Modular UPS System High Flexibility For Sensitive Equipment

  • High Light

    commercial ups battery backup

    ,

    modular type ups

  • Input Voltage
    380V/400V/415V (228V-476V;-20%~25% At Full Load ; Linear Derating At -25% ~- 40%; Can Take 70% Load At -40%)
  • Inverter Output Voltage
    50/60Hz(40-70HZ)
  • Input Power Factor
    Full Load>0.99 ,Half Load >0.98
  • Bypass Voltage Range
    Default Value Is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , Other Ranges Can Be Set Via Software
  • Overload Capacity
    Long Term At 135% Rated Load ,150%1000% 100ms
  • System Frequency
    50Hz/60Hz (Settable)
  • Place of Origin
    Shenzhen, China
  • Brand Name
    CONSNANT
  • Certification
    CE, ISO9001, ISO14001
  • Model Number
    CNM330
  • Minimum Order Quantity
    1 Unit
  • Price
    Negotiable
  • Packaging Details
    Export Standard Package
  • Delivery Time
    20days after receiving 30% deposit
  • Payment Terms
    T/T, L/C, Western Union
  • Supply Ability
    500 pieces per month

Single Cabinet Automation Modular UPS System High Flexibility For Sensitive Equipment

Industrial Automation Modular UPS System

High Flexibility And Adaptation 30 - 300KVA



CNM330 series is modular online UPS for sensitive equipment. The single cabinet power rating covers from 10KVA to 300KVA which delivers the best of combination of reliability, hot-swappable and flexibility. With the latest IGBT three-level technology and DSP control, CNM330 achieves a high input power factor, low THDi Modular design with N+X redundancy and online hot swapping ,easy to expand the capacity Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance and reduced size



Application:


Application IDC(Internet Data Center)

Computing center

ISP (Internet Service Provider )

Telecom , Finance, bank and securities , Tax

Hospital system , industrial automation

Precision equipment, etc.



Features:

 

■ Superior energy saving : efficiency > 96% at 50%-75% rated load
■ Easy-to-install: top or bottom cabling, no need of input cabling cabinet.
■ Easy-to-maintain: full front access, UPS, failed part can be replaced shortly
■ Easy-to-modify: the number of battery cells can be configured flexibly, so the original batteries can be used when modifying the legacy system; moreover, the battery cell can be replaced in time when it fails without interrupting the normal operation of UPS. Power module supports hot swappable,
■ Extra large LCD that can display 12 language (Chinese ,English ,Russian, French ,Spanish and so on).
■ Provide large LCD touch screen (optional)
■ Each UPS modules provide 4.5KW charge capacity. equivalent to 10 to 12A
■ Advanced DSP full digital control technologies 
■ Advanced distributed active parallel technology 
■ Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges
■ Intelligent battery management maintains battery automatically to prolong the battery life
■ The machine system for modular structure, consists of 1 to 10 module's biggest single module to 30kw
■ UPS  capacity upgrade extremely simple.
■ Super ability for overload and short circuit, ensure the system stability and safety under the limit state of system

■ RS232,RS485,dry contact, SNMP card, EPO, generator port
■ System efficiency >96% at load above 50%, >95% at load above 25%





Technical Specifications:

 

Model CNM330 20-300KVA
Capacity 20-300KVA
Main Input  
Input Voltage 380V/400V/415V
Input Frequency Range 50/60Hz
Power Factor Full load>0.99 ,Half load >0.98
THDi THDi<3%
Input Power Soft-start Function 5-30s settable
Input Voltage Ranges 228V-476V;-20%~25% at Full load ; linear derating at -25% ~- 40%; can take 70% load at -40%
Frequency Range 40-70HZ
Battery
Battery Voltage ±240VDC(Default),12V Battery 30~40pcs can be choose
Charge Voltage Accuracy ±1%
Bypass
Bypass Input Voltage 380/400/415VAC 3-phase 4-wire
Voltage Range Default value is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , other ranges can be set via software
Overload Capacity

Long term at 135% rated load ,150%<load<180% more than 10 min,

load>1000% 100ms

Output
Inverter Output Voltage 380/400/415VAC 3-phase 4-wire
Voltage Accuracy ±0.5% ( balanced load ) , ±1% ( unbalanced load )
THDV THDV<1% (linear load) , THDV<3% (nonlinear load)
Power Factor 0.9
Three Phase Angle Accuracy 120°± 0.5°
Current Crest Ratio 3:1
Overload Capacity 110%1h,125%10mins,150%1mins,>150%200ms
Transfer Time 0ms,15ms (Eco Mode)
System
Frequency 50Hz/60Hz (Settable)
Mains Synchronization Range ±2Hz(Default value), adjustable with step of 0.5Hz within range of +/- 0.5Hz - 3Hz
Protection Level IP20
Operation Temperature 0-40ºC
Storage Temperature -25ºC~70ºC ( without battery)
Humidity 0-95% (no-condensing)
Noise(dB) 55-62dB,Adjusted with load
Weight module:PM20 20KVA power module : 35KG
module:PM30 30KVA power module : 35KG
module:PM40 40KVA power module : 35KG
Dimension (W x D x H)mm 3 module cabinet 600X900X1135
5 module cabinet(5 battery cabinet option) 600X1100X2070/
6 module cabinet 600X900X1535
10 module cabinet 900X900X2080
power module 440X650X132(3U)(10KVA/20KVA/30KVA)


(Optional South America 208V must be derating use)

 

 

Single Cabinet Automation Modular UPS System High Flexibility For Sensitive Equipment 0

 

Single Cabinet Automation Modular UPS System High Flexibility For Sensitive Equipment 1