Building B6, Junfeng Industrial Park, Fuyong Town, Bao'an District, Shenzhen City, 518103 P.R.China
Home ProductsModular UPS System

Low THDi Modular UPS System Strong Overload Ability Full DSP Control High Stability

Low THDi Modular UPS System Strong Overload Ability Full DSP Control High Stability

    • Low THDi Modular UPS System Strong Overload Ability Full DSP Control High Stability
    • Low THDi Modular UPS System Strong Overload Ability Full DSP Control High Stability
    • Low THDi Modular UPS System Strong Overload Ability Full DSP Control High Stability
  • Low THDi Modular UPS System Strong Overload Ability Full DSP Control High Stability

    Product Details:

    Place of Origin: Shenzhen,China
    Brand Name: CONSNANT
    Certification: CE,ISO9001,ISO14001
    Model Number: CNM330

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 Unit
    Price: Negotiable
    Packaging Details: Wooden case
    Delivery Time: 20 days after receiving 30% deposit
    Payment Terms: L/C, T/T, Western Union
    Supply Ability: 2000 pieces per year
    Contact Now
    Detailed Product Description
    Input Voltage: 380V/400V/415V Input Power: Full Load>0.99 ,Half Load >0.98
    Inverter Output Voltage: 380/400/415VAC 3-phase 4-wire Power Factor: 0.9
    Current Crest Ratio: 3:1 IP: 20

    Low THDi Modular UPS System With Strong Overload Ability 30 - 1200KVA


    Description:

     


    CNM330 series is modular online UPS for sensitive equipment. The single cabinet power rating covers from 10KVA to 300KVA which delivers the best of combination of reliability, hot-swappable and flexibility. With the latest IGBT three-level technology and DSP control, CNM330 achieves a high input power factor, low THDi Modular design with N+X redundancy and online hot swapping ,easy to expand the capacity Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance and reduced size

     


    Application:

     


    Application IDC(Internet Data Center)
    Computing center
    ISP (Internet Service Provider )
    Telecom , Finance, bank and securities , Tax
    Hospital system , industrial automation
    Precision equipment, etc.
     


    Working principle:

    Modular UPS use double conversion on-line structure, including the rectifier, inverter, battery charger, control circuit, the input and output battery connector breaker. Have function that is input power factor compensation. All modules can be online hot-swappable, provide the highest level of availability, and maintainability.
    If one power module failure will not affect the system normal working, power module can be online hot-swappable all power module parallel is managed by the control board, in accordance with the unified parameters running, one power module fault can be automatically exit parallel system, will not cause harm to the whole parallel system.

    Modular UPS system use independent static bypass module, do not use multiple static bypass structure, avoid caused overload damage modules because of multiple bypass module uneven current when UPS turn to bypass working. The module parallel output voltage accuracy is±1%, parallel circulation current< 1%.
    Static bypass module contains bypass static switch only, excluded static switch of the main circuit output; therefore, replacing static bypass module will not cause the system power down or transfer manual maintenance bypass, which can realize online hot-swap replacement.
     

     


    Rich Management Interface

    Advanced battery management

    • All floating automatic conversion
    • Temperature compensation
    • Discharge to suspend automatic voltage regulation
    • Battery self-diagnosis and self-inspection
    • Battery capacity prediction
    • Discharge time estimates
    • Low voltage forecasting warning

     

    Data recorder:

    Every 10 ms records a core electrical data, and in Fault occurs, the freezing failure 1 to 1.5 before work. The core of the cycle frequency electrical data Accurately record the cause of failure, to help the accident diagnosis and accurate positioning Rapid diagnosis to improve maintainability, the data will be recorded before a failure or overload occur.

     

    High Availability Configuration Structure

    1. Static switch module:
    • System standard configuration module
    • Adopts SCR and AC contactor in parallel
    • High reliability, strong overload ability: 1000% for 1 min
    • Transfer time less than 1ms
    • Have strong self-test, inter-lock and full-protection function

     

    2. Power Module:

    • Freedom choice of capacity configuration according demand, easy to expand
    • Online double-conversion design to ensure the output quality
    • Each module has independent digital intelligent control
    • Each module can work independently and has a separate charging system
    • All modules can be hot-swappable, easy for online maintenance
    • Each UPS module provide 4.5KW charge capacity, equivalent to 10 to 12A


    3. Rich Management Interface

     

    • All floating automatic conversion
    • Temperature compensation
    • Discharge to suspend automatic voltage regulation
    • Battery self-diagnosis and self-inspection
    • Battery capacity prediction
    • Discharge time estimates
    • Low voltage forecasting warnin

     


    Advanced self-diagnosis:

     

    • Inverter and rectifier circuit working condition monitoring
    • Battery capacity and status detection
    • Equipment working environment temperature testing
    • Ease of maintenance and management of equipment
    • Can each fan of fault detection, and replace the fan without power


    Technical Specifications:
     

    Model CNM330 20-300KVA
    Capacity 20-300KVA
    Main Input  
    Input Voltage 380V/400V/415V
    Input Frequency Range 50/60Hz
    Power Factor Full load>0.99 ,Half load >0.98
    THDi THDi<3%
    Input Power Soft-start Function 5-30s settable
    Input Voltage Ranges 228V-476V;-20%~25% at Full load ; linear derating at -25% ~- 40%; can take 70% load at -40%
    Frequency Range 40-70HZ
    Battery
    Battery Voltage ±240VDC(Default),12V Battery 30~40pcs can be choose
    Charge Voltage Accuracy ±1%
    Bypass
    Bypass Input Voltage 380/400/415VAC 3-phase 4-wire
    Voltage Range Default value is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , other ranges can be set via software
    Overload Capacity Long term at 135% rated load ,150%<load<180% more than 10 min,
    load>1000% 100ms
    Output
    Inverter Output Voltage 380/400/415VAC 3-phase 4-wire
    Voltage Accuracy ±0.5% ( balanced load ) , ±1% ( unbalanced load )
    THDV THDV<1% (linear load) , THDV<3% (nonlinear load)
    Power Factor 0.9
    Three Phase Angle Accuracy 120°± 0.5°
    Current Crest Ratio 3:1
    Overload Capacity 110%1h,125%10mins,150%1mins,>150%200ms
    Transfer Time 0ms,15ms (Eco Mode)
    System
    Frequency 50Hz/60Hz (Settable)
    Mains Synchronization Range ±2Hz(Default value), adjustable with step of 0.5Hz within range of +/- 0.5Hz - 3Hz
    Protection Level IP20
    Operation Temperature 0-40ºC
    Storage Temperature -25ºC~70ºC ( without battery)
    Humidity 0-95% (no-condensing)
    Noise(dB) 55-62dB,Adjusted with load
    Weight module:PM20 20KVA power module : 35KG
    module:PM30 30KVA power module : 35KG
    module:PM40 40KVA power module : 35KG
    Dimension (W x D x H)mm 3 module cabinet 600X900X1135
    5 module cabinet(5 battery cabinet option) 600X1100X2070/
    6 module cabinet 600X900X1535
    10 module cabinet 900X900X2080
    power module 440X650X132(3U)(10KVA/20KVA/30KVA)


    (Optional South America 208V must be derating use)
     

     

    FAQ:

     

    Q1: What's included in products?

    A: It is included UPS unit, user manual, 2% spare parts for emergency, test certificate(optional)


    Q2. Your UPS meet CE requirements?

    A:Our UPS is with the certificate of CE, ISO and Chinese TLC certificates.

     

    Q3: Can we change the shape, size, color or printing based on the original design?

    A: Yes, and OEM, ODM accepted


    Q4:. Can you design one specially?

    A: Yes

     


    Consnant Modular UPS in hospital

    Low THDi Modular UPS System Strong Overload Ability Full DSP Control High Stability

    Low THDi Modular UPS System Strong Overload Ability Full DSP Control High Stability

    Contact Details
    Shenzhen Consnant Technology Co., Ltd.

    Contact Person: sales

    Send your inquiry directly to us (0 / 3000)

    Other Products