Emergency Power Off Online High Frequency UPS Single Phase For Small Data Base

Emergency Power Off Online High Frequency UPS Single Phase For Small Data Base

  • High Light

    online ups power supply

    ,

    computer ups power supply

  • Voltage Precision
    208/220/230/240X(1±2%)VAC
  • Frequency Precision
    50/60Hz±0.05Hz
  • Power Factor
    0.8
  • Harmonic Distortion
    50/60Hz±0.05Hz
  • Overload Capacity
    Load > 110% For 47s; Load > 150% For 25s; Load > 200% For 300ms;
  • Current Crest Ratio
    3:1
  • Place of Origin
    Shenzhen, China
  • Brand Name
    CONSNANT
  • Certification
    CE, ISO9001, ISO14001
  • Model Number
    CNH110
  • Minimum Order Quantity
    20
  • Price
    Negotiable
  • Packaging Details
    Export Standard Package
  • Delivery Time
    10-30 days against the order quantity
  • Payment Terms
    T/T, L/C, Western Union
  • Supply Ability
    50000 pieces per year

Emergency Power Off Online High Frequency UPS Single Phase For Small Data Base

Micro Data Center​ High Frequency Online UPS Single Phase 2 Wire + G 50 / 60HZ
 
Application:
 
Networks, computer, micro data center, small data base
Key Features:
 
 

  •  DSP technology
  • Output power factor up to 0.8 
  • Total power factor up to 90% 
  • Emergency Power Off (EPO): UPS can be instantly shut off in case of any emergency;
  • Compliance with EMC requirements of IEC61000-4,provide your device a clean electric environment.
  • Active power factor correction (PFC) technology
  • Excellent input frequency range 
  • Parallel Kit
  • Compact Design
  • Lower Noise
  • Super overload Capacity load

 

 
Details:
 
Rich Communication and Monitoring
RS232,USB interface and communication cable for local or remote power supply management; SNMP Card(Optional),USB port(Optional)
 
User-friendly interface
LCD display real-time UPS status,  through the LCD display panel user can set output voltage and frequency, ECO mode , to operate the UPS conveniently .
 
Intelligent battery management:
1. With its advanced intelligent charge control mode, UPS can automatically select the optimal charge mode as per the battery type and conditions, thus further maximizing the lifespan of battery bank.In additional, the system can periodically conduct the charge & discharge management for the battery bank. User also can select the battery voltage (192V or 240V) on demands.
2. The user can query and set the proper UPS control parameters for intelligent UPS management; automatically identify and adapt to 50/60Hz power supply system, fulfilling the requirements in various power supply systems;
3. Perfect failure protection and alarm function: provide complete failure protection and clear alarm notification function in case of I/O over-voltage or under-voltage, battery overcharge or under-voltage, overload, and short circuit.
 
Intelligent Power monitoring and Management Software WinPower 2003 :
Support :
 

  1.   Microsoft Windows95/Me/NT/2000/XP/Unux operating system. Suit for TCP/IP local area network;
  2. TCP/IP network monitoring ; Provide a hierarchical directory structure management network; Unusual event can be notified to user through broadcast , e-mail, messenger call or mobile messager; Automatically detective the UPS model and the communication port; Provide password protection;
  3.  Timing boot up / shut off UPS function;
  4.  Timing UPS self-test function;
  5. Graphically displayed UPS status function in real time;
  6. Network to deactivate the function of multiple servers and workstations;
  7.  Accept the abnormal power;
  8.  To shut off most of the applications and the preservation of related document;
  9.  The online help function; with data records (including mains, ups, load, battery), and event function,to convenient the system administrator for the routine maintenance.

 
Technical specifications:
 
 

ModelCNH110 1-10KVA
1KS1K2KS2K3KS3K6KS6K10KS10K
Capacity1KVA/800W2KVA/1600W3KVA/2400W6KVA/4800W10KVA/8000W
Input
Nominal Voltage208/220/230/240VAC Single phase 2 wire+G
Nominal Frequency50/60HZ
Voltage Range115~300VAC120~275VAC
Frequency Range50HZ: (46~54HZ); 60HZ:(56HZ~64HZ)
Power Factor> 0.980.99
Output
Voltage Precision208/220/230/240X(1±2%)VAC
Frequency Precision50/60Hz±0.05Hz
Power Factor0.80.8/0.9(Optional)
Harmonic DistortionLinear load<3% Non-linear<6%
Overload Capacityload > 110% for 47s;
load > 150% for 25s;
load > 200% for 300ms;
105% < load ≤125% for 60s;
125% < load ≤150% for 30s;
load >150% for 0.5s.
Current Crest Ratio3:1
Transfer Time0 ms(AC mode↔DC mode);(AC mode↔Bypass<4ms)
Battery
DC Voltage36VDC72VDC96VDC192 or 240VDC(Optional)
Recharge Time5 hours to 90%(it means standard model which battery inside UPS)
Recharge Current1A7A1A8A1A8A2A4A2A4A
Panel DisplayLCD
Working Environment
Temperature0ºC~40ºC
Relative Humidity0~95%(Non-condensing)
Storage Temperature-25ºC~55ºC
Elevation1500m
Noise Level<45dB<50dB<50dB

 
 
Standard: 
 
EMS:

  • ESD    IEC61000-4-2 Level4
  • RS      IEC61000-4-3 Level3
  • EFT    IEC61000-4-4 Level4
  • Surge IEC61000-4-5 Level4

EMI:

  • Conducted EN55022 Class A
  • Radiated    EN55022 Class A

 
 
Why Choose Us?
 
We have experienced team for more ten years and high-tech equipment.
Our products is with ICE, ISO and Chinese TLC
We can make product according to your requirements, such as your size, color, design, and your logo.
We can offer you very competitive price.
You can get expert guides from us all the time.
Emergency Power Off Online High Frequency UPS Single Phase For Small Data Base 0