Three phase Solar Power Storage System include Solar Controller High Efficiency Provide Uninterruptible backup power
SUN SGS-i Series
Smart Gird Interactive Inverter with MPPT Sloar Controller
•Three phase IGBT inverter Technology(SPWM)
with output isolate transformer.
•Include PWM with MPPT solar controller(10-30kwp)
•Provide uninterruptible backup power to load
when utility grid line is not available
•Smart battery IGBT rectifier charging for small battery capacity
•Feeding excess energy back to grid line
With Function parallel N+X upto 8 pcs(option)
•High efficiency >98%
•IGBT Rectifier input power factor>0.99,THDi<5%
•Generator connected signal and automatic start
generator signal when generator provide as other
energy source of the system
•Transfer time 4-10ms Inverter to utility
•Special design for using at high grid fluctuation area
•User settable operation:
1.Excess PV energy to utility line
2.No PV energy to utility line,PV energy only supplies to load.
3.Setable & %Control Excess PV energy to utility line
4.Setable battery %DoD and %SoC
•Battery temperature compensation
(temperature sensor is not included)
HMI 7inch touch screen,Communication with RS232,RS485/Modbus and dry contact
•ISO9001 and ISO14001 certified manufacturer.
Applications:
Technology Specifications:
Model | SGS-10i | SGS-15i | SGS-20i | SGS-30i | SGS-40i | SGS-50i | SGS-60i | SGS-75i | SGS-100i | |
SMART GRID SYSTEM | Appilcation | Smart Drid System for Mini Plant | ||||||||
Control& Technology |
Smart DSP Control Double Conversion IGBT Technology | |||||||||
HYBRID SYSTEM | Inverter | 10kw | 15kw | 20kw | 30KW | 40kw | 50kw | 60kw | 75kw | 100kw |
Battery Storage | 100-200Ah | 150-300Ah | 200-400Ah | 250-500Ah | 400-800Ah | 450-1000Ah | 500-1000Ah | 750-1500Ah | 1000-2000Ah | |
PV System |
10-12 kwp |
15-17 kwp |
20-25 kwp |
30-40kwp |
40-45 kwp |
50-60 kwp |
60-70 kwp |
75-90 kwp |
100-120 kwp |
|
Generation | 10kw | 15kw | 20kw | 30KW | 40kw | 50kw | 60kw | 75kw | 100kw | |
Electrical Grid |
10kw /15A |
15kw /25A |
20kw /30A |
30kw-55A |
40kw /60A |
50kw /75A |
60kw /91A |
75kw /115A |
100 kw/152A |
|
BATTERY VOLTAGE | Normal Voltage | 240 vdc | 400 vdc | |||||||
Voltage Range | 210-290 vdc | 368-480 vdc | ||||||||
Max AC Charming Current |
40A | 60A | 75A | 130A | 150A | 190A | 225A | 300A | 375A | |
Maximum Battery current |
40A | 60A | 75A | 130A | 150A | 190A | 225A | 300A | 375A | |
IGBT CHARGER/RECTIFIER | Voltage Charge | 250-290 vdc | ||||||||
Charging Current(MAX) | 20Adc | 30Adc | 38Adc | 60Adc | 75Adc | 75Adc | 110Adc | 150Adc | 190Adc | |
AC INPUT GRID LINE GENERATOR | Generator Power | 10kw | 15kw | 20kw | 30KW | 40kw | 50kw | 60kw | 75kw | 100kw |
Voltage | L-N:380/400/415 Vac+/-10% | |||||||||
Phase | 3Phase4WIRE + PE | |||||||||
Frequency | 50/60 Hz±3% | |||||||||
Function start/stop | Relay dry contact 10A(ACC on and start) | |||||||||
AC OUTPUT |
Power Continuous (PF=1) |
10kw | 15kw | 20kw | 30KW | 40kw | 50kw | 60kw | 75kw | 100kw |
Output Voltage | L-N:380/400/415Vac,L-N:220/230/240Vac 3Phase 4Wire + PE | |||||||||
Voltage Regulation | +/-5% steady load .<4% step load within 0.1sec | |||||||||
Frequency | 50/60Hz Hz ± 0.1% | |||||||||
Total Harmonic Distortion | THD<3%(linear load) | |||||||||
Wave form | Pure sine wave | |||||||||
Overload Capability | >125% load for 10 min,150% load for 10sec,200% load at 2sec | |||||||||
Isolation | Type | Galvanic isolation | ||||||||
EFFICIENCY | Inverter Peak(MAX) | >94% | >95% | |||||||
PROTECTION | System | Over current,Overload,Over tempeerature,Short circuit,Over voltage,Low battery and Over battery voltage | ||||||||
IP Level | IP20 | |||||||||
INDICATOR | HMI 7 inch Display | AC,Inverter,overload and Fault Output power ,AC Energy Hour,today,Month,Year,AC Energy ACC,Battery voltage,Load,DC current,inverter status and Fault | ||||||||
ALARM | Operation Alarm | Low battery ,Overload,Over temperature and fault | ||||||||
COOLING | System Operate | Automatic cooling fans | ||||||||
ENVIRONMENT | Temperature | 0-45℃ | ||||||||
Relative Humidity | 0-95%(Non-condensing) | |||||||||
DESIGN REGULATION PHYSICAL | Tested According to | AS/NC 3100,EN61000-6-1/-3,EN50178 and IEC 62040 | ||||||||
Dimension WxDxH(mm) | 550*890*1550(with SPC250-64) | |||||||||
Weight(kg) | 200 | 250 | 250 | 250 | 300 | 550 | 600 | 600 | 600 |
Model | SGS-120i | SGS-150i | SGS-160i | SGS-200i | SGS-225i | SGS-250i | |
SMART GRID SYSTEM | Appilcation | Smart Drid System for Mini Plant | |||||
Control& Technology |
Smart DSP Control Double Conversion IGBT Technology | ||||||
HYBRID SYSTEM | Inverter | 120kw | 150kw | 160kw | 200KW | 225kw | 250kw |
Battery Storage |
1250-2500 Ah |
1500-3000Ah | 1600-3200Ah | 2000-4000aH | 2000-4000aH | 2500-5000Ah | |
PV System |
120-135 kwp |
150-170 kwp |
160-180 kwp |
200-250kwp |
200-230 kwp |
250-280kwp | |
Generation | 120kw | 150kw | 160kw |
200 KW |
225kw | 250kw | |
Electrical Grid |
120kw/ 182A |
150kw /227A |
160kw /243A |
200kw /303A |
250kw /380A |
250kw/380A | |
BATTERY VOLTAGE | Normal Voltage | 240 vdc | |||||
Voltage Range | 368-480 vdc | ||||||
Max AC Charming Current |
450A | 560A | 600A | 750A | 800A | 935A | |
Maximum Battery current |
450A | 560A | 600A | 750A | 800A | 935A | |
IGBT CHARGER/RECTIFIER | Voltage Charge | 400-480 Vdc | |||||
Charging Current (MAX) |
225Adc | 280Adc | 300Adc | 375Adc | 400Adc | 465Adc | |
AC INPUT GRID LINE GENERATOR |
Generator Power |
120kw | 150kw | 160kw | 200KW | 225kw | 250kw |
Voltage | L-N:380/400/415 Vac+/-10% | ||||||
Phase | 3Phase 4WIRE + PE | ||||||
Frequency | 50/60 Hz±3% | ||||||
Function start/stop | Relay dry contact 10A(ACC on and start) | ||||||
AC OUTPUT |
Power Continuous (PF=1) |
120kw | 150kw | 160kw | 200KW | 225kw | 250kw |
Output Voltage | L-N:380/400/415 Vac,L-N:220/230/240 Vac 3Phase 4Wire + PE | ||||||
Voltage Regulation | +/-5% steady load .<4% step load within 0.1sec | ||||||
Frequency | 50/60Hz Hz ± 0.1% | ||||||
Total Harmonic Distortion | THD<3%(linear load) | ||||||
Wave form | Pure sine wave | ||||||
Overload Capability | >125% load for 10 min,150% load for 10sec,200% load at 2sec | ||||||
Isolation | Type | Galvanic isolation | |||||
EFFICIENCY | Inverter Peak(MAX) | >95% | |||||
PROTECTION | System | Over current,Overload,Over tempeerature,Short circuit,Over voltage,Low battery and Over battery voltage | |||||
IP Level | IP20 | ||||||
INDICATOR | HMI 7 inch Display | AC,Inverter,overload and Fault Output power ,ACEnergy Hour,today,Month,Year,AC Energy ACC,Battery voltage,Load,Dccurrent,inverter status and Fault | |||||
ALARM | Operation Alarm | Low battery ,Overload,Over temperature and fault | |||||
COOLING | System Operate | Automatic cooling fans | |||||
ENVIRONMENT | Temperature | 0-45℃ | |||||
Relative Humidity | 0-95%(Non-condensing) | ||||||
DESIGN REGULATION PHYSICAL | Tested According to | AS/NC 3100,EN61000-6-1/-3,EN50178 and IEC 62040 | |||||
Dimension WxDxH(mm) |
1600*1000*2000 | ||||||
Weight(kg) | 1200 | 1300 | 1350 | 1400 | 1450 | 1500 |