Micro Data Center High Frequency Online UPS Single Phase 2 Wire + G 50 / 60HZ
Application:
Networks, computer, micro data center, small data base
Details:
Rich Communication and Monitoring
RS232,USB interface and communication cable for local or remote power supply management; SNMP Card(Optional),USB port(Optional)
User-friendly interface
LCD display real-time UPS status, through the LCD display panel user can set output voltage and frequency, ECO mode , to operate the UPS conveniently .
Intelligent battery management:
1. With its advanced intelligent charge control mode, UPS can automatically select the optimal charge mode as per the battery type and conditions, thus further maximizing the lifespan of battery bank.In additional, the system can periodically conduct the charge & discharge management for the battery bank. User also can select the battery voltage (192V or 240V) on demands.
2. The user can query and set the proper UPS control parameters for intelligent UPS management; automatically identify and adapt to 50/60Hz power supply system, fulfilling the requirements in various power supply systems;
3. Perfect failure protection and alarm function: provide complete failure protection and clear alarm notification function in case of I/O over-voltage or under-voltage, battery overcharge or under-voltage, overload, and short circuit.
Intelligent Power monitoring and Management Software WinPower 2003 :
Support :
Microsoft Windows95/Me/NT/2000/XP/Unux operating system. Suit for TCP/IP local area network;
TCP/IP network monitoring ; Provide a hierarchical directory structure management network; Unusual event can be notified to user through broadcast , e-mail, messenger call or mobile messager; Automatically detective the UPS model and the communication port; Provide password protection;
Timing boot up / shut off UPS function;
Timing UPS self-test function;
Graphically displayed UPS status function in real time;
Network to deactivate the function of multiple servers and workstations;
Accept the abnormal power;
To shut off most of the applications and the preservation of related document;
The online help function; with data records (including mains, ups, load, battery), and event function,to convenient the system administrator for the routine maintenance.
Technical specifications:
Model | CNH110 1-10KVA | ||||||||||||||||
1KS | 1K | 2KS | 2K | 3KS | 3K | 6KS | 6K | 10KS | 10K | ||||||||
Capacity | 1KVA/800W | 2KVA/1600W | 3KVA/2400W | 6KVA/4800W | 10KVA/8000W | ||||||||||||
Input | |||||||||||||||||
Nominal Voltage | 208/220/230/240VAC Single phase 2 wire+G | ||||||||||||||||
Nominal Frequency | 50/60HZ | ||||||||||||||||
Voltage Range | 115~300VAC | 120~275VAC | |||||||||||||||
Frequency Range | 50HZ: (46~54HZ); 60HZ:(56HZ~64HZ) | ||||||||||||||||
Power Factor | > 0.98 | 0.99 | |||||||||||||||
Output | |||||||||||||||||
Voltage Precision | 208/220/230/240X(1±2%)VAC | ||||||||||||||||
Frequency Precision | 50/60Hz±0.05Hz | ||||||||||||||||
Power Factor | 0.8 | 0.8/0.9(Optional) | |||||||||||||||
Harmonic Distortion | Linear load<3% Non-linear<6% | ||||||||||||||||
Overload Capacity | load > 110% for 47s; load > 150% for 25s; load > 200% for 300ms; |
105% < load ≤125% for 60s; 125% < load ≤150% for 30s; load >150% for 0.5s. |
|||||||||||||||
Current Crest Ratio | 3:1 | ||||||||||||||||
Transfer Time | 0 ms(AC mode↔DC mode);(AC mode↔Bypass<4ms) | ||||||||||||||||
Battery | |||||||||||||||||
DC Voltage | 36VDC | 72VDC | 96VDC | 192 or 240VDC(Optional) | |||||||||||||
Recharge Time | 5 hours to 90%(it means standard model which battery inside UPS) | ||||||||||||||||
Recharge Current | 1A | 7A | 1A | 8A | 1A | 8A | 2A | 4A | 2A | 4A | |||||||
Panel Display | LCD | ||||||||||||||||
Working Environment | |||||||||||||||||
Temperature | 0ºC~40ºC | ||||||||||||||||
Relative Humidity | 0~95%(Non-condensing) | ||||||||||||||||
Storage Temperature | -25ºC~55ºC | ||||||||||||||||
Elevation | 1500m | ||||||||||||||||
Noise Level | <45dB | <50dB | <50dB |