Technical Specifications:
Model | CNS115-10 | CNS115-15 | CNS115-20 | CNS115-25 | CNS115-30 | CNS115-40 | CNS115-50 | |
INVERTER | Power | 10kw | 15kw | 20kw | 25kw | 30kw | 40kw | 50kw |
Battery Storage | 100 - 200Ah | 150 - 300Ah | 200 - 400Ah | 250 - 500Ah | 300 - 600Ah | 350 - 750Ah | 450 - 900Ah | |
PV System | 10 - 12kwp | 15 - 17kwp | 20 - 25kwp | 25 - 30kwp | 30 - 35kwp | 35 - 40kwp | 45 - 50kwp | |
Generator | 10kw | 15kw | 20kw | 25kw | 30kw | 40kw | 50kw | |
Electrical Grid | 10kw / 45A | 15kw / 68A | 20kw / 90A | 25kw / 115A | 30kw / 136A | 40kw / 160A | 50kw / 227A | |
MPPT Solar Controller | 240VDC | 50A | 70A | 100A | 100A | 150A | 180A | 200A |
BATTERY VOLTAGE | Normal Voltage | 240 Vdc | ||||||
Voltage Range | 210 - 290 Vdc | |||||||
Max . AC Charging Current | 40A | 60A | 75A | 90A | 112A | 130A | 200A | |
Maximum Battery current | 42A | 63A | 85A | 105A | 125A | 145A | 210A | |
AC CHARGE | Voltage Charge | 250 - 290 Vdc | ||||||
Charging Current ( Max .) | 20Adc | 30Adc | 40Adc | 50Adc | 60Adc | 75Adc | 100Adc | |
AC INPUT GRID LINE | Generator Power | 10kw | 15kw | 20kw | none | none | none | none |
Voltage | L - N : 220 / 230 / 240 Vac +/ - 10 % | |||||||
GENERATOR | Phase | 1Phase 2Wire + PE | ||||||
Frequency | 50 / 60 Hz ± 3 % | |||||||
Function start / stop | Relay dry contact 10A ( ACC on and start ) | |||||||
Power Continuous ( PF = 1 ) | 10kw | 15kw | 20kw | 25kw | 30kw | 40kw | 50kw | |
AC OUTPUT | Output Voltage | L - N : 220 / 230 / 240 Vac 1Phase 2Wire + PE | ||||||
Voltage Regulation | +/ - 5 % steady load .< 4 % step load within 0 . 1sec | |||||||
Frequency | 50 / 60 Hz ± 0 . 1 % | |||||||
Total Harmonic Distortion | THD < 3 % ( linear load ) | |||||||
Wave Form | Pure sine wave | |||||||
Overload Capability | > 125 % load for 10 min , 150 % load for 30sec ,> 150 % load for 10sec , 200 % load at 2sec | |||||||
ISOLATION | Type | Galvanic isolation | ||||||
EFFICIENCY | Ivnerter Peak ( Max .) | > 90 % | ||||||
PROTECTION | System | Over current , Overload , Over temperature , Short circuit , Over voltage , Under voltage , Low battery and Over battery voltage | ||||||
IP level | IP20 | |||||||
ALARM | Operation Alarm | Low battery , Overload , Over temperature and Fault | ||||||
COOLING | System Operate | Temperature control | ||||||
ENVIRONMENT | Tenmperature | 0 - 45 ℃ | ||||||
Relative Humidity | 0 - 95 %( Non - condensing ) | |||||||
DESIGN REGULATION | Tested According to | AS / NZ 3100 , EN61000 - 6 - 1 / - 3 , EN50178 and IEC 62040 | ||||||
Dimension WxDxH ( mm .) | 800*1030*1655 (with built-in MPPT) | |||||||
PHYSICAL | Weight ( kg ) | 200 | 250 | 250 | 250 | 300 | 550 | 600 |