Three Phase High Capacity UPS System Parallel Redundancy Online 30 - 180KVA

Three Phase High Capacity UPS System Parallel Redundancy Online 30 - 180KVA

  • High Light

    redundant ups power supply

    ,

    modular type ups

  • Communication Ports
    RS232,RS485,dry Contact, SNMP Card, EPO, Generator Port
  • System Efficiency
    >96% At Load Above 50%, >95% At Load Above 25%
  • PowerModule Capacity
    20/30/40KVA Each
  • Display
    LCD/LED(optianl)
  • Phase
    Three Phase
  • Cabinet Color
    Black/white
  • Place of Origin
    Shenzhen, China
  • Brand Name
    CONSNANT
  • Certification
    CE, ISO9001, ISO14001
  • Model Number
    CNM330-180K
  • Minimum Order Quantity
    1 Unit
  • Price
    Negotiable
  • Packaging Details
    Export Standard Package
  • Delivery Time
    20days after receiving 30% deposit
  • Payment Terms
    T/T, L/C, Western Union
  • Supply Ability
    500 pieces per month

Three Phase High Capacity UPS System Parallel Redundancy Online 30 - 180KVA

High Efficiency Modular UPS System Parallel Redundancy Online
30 - 180KVA
CNM330 series is modular online UPS for sensitive equipment. The single cabinet power rating covers from 10KVA to 300KVA which delivers the best of combination of reliability, hot-swappable and flexibility. With the latest IGBT three-level technology and DSP control, CNM330 achieves a high input power factor, low THDi Modular design with N+X redundancy and online hot swapping ,easy to expand the capacity Full DSP control of high stability, reliability and safety Integrated IGBT module with improved performance and reduced size
 
Application:

Application IDC(Internet Data Center)
Computing center
ISP (Internet Service Provider )
Telecom , Finance, bank and securities , Tax
Hospital system , industrial automation
Precision equipment, etc.

 
Features:
 

  • Efficiency > 96% at 50%-75% rated load, and > 95% at 25% rated load; Input PF > 0.99,input THDi<3%
  • Top or bottom cabling, no need of input cabling cabinet.
  • Full front access, UPS, failed part can be replaced shortly
  • The number of battery cells can be configured flexibly, so the original batteries can be used when modifying the legacy system; moreover, the battery cell can be replaced in time when it fails without interrupting the normal operation of UPS.
  • Extra large LCD that can display 12 language (Chinese ,English ,Russian, French ,Spanish and so on).
  • Each UPS modules provide 4.5KW charge capacity. equivalent to 10 to 12A
  • Advanced DSP full digital control technologies realize higher system stability, online capacity expansion and maintenance
  • Advanced distributed active parallel technology realizes parallel operation of 4 UPS units and online capacity expansion without centralized bypass cabinet
  • Adaptive to severe power grid environment due to extra wide input voltage and frequency ranges
  • Intelligent battery management maintains battery automatically to prolong the battery life
  • The machine system for modular structure, consists of 1 to 10 module's biggest single module to 30kw
  • UPS power module supporting hot swappable, capacity upgrade extremely simple.
  • Super ability for overload and short circuit, ensure the system stability and safety under the limit state of system
  • Overload Capacity: Long term at 135% rated load ,150%<load<180% more than 10 min,
    load>1000% 100ms

 
Technical Specifications:
 

 

Model CNM330 20-300KVA
Capacity 20-300KVA
Main Input  
Input Voltage 380V/400V/415V
Input Frequency Range 50/60Hz
Power Factor Full load>0.99 ,Half load >0.98
THDi THDi<3%
Input Power Soft-start Function 5-30s settable
Input Voltage Ranges 228V-476V;-20%~25% at Full load ; linear derating at -25% ~- 40%; can take 70% load at -40%
Frequency Range 40-70HZ
Battery
Battery Voltage ±240VDC(Default),12V Battery 30~40pcs can be choose
Charge Voltage Accuracy ±1%
Bypass
Bypass Input Voltage 380/400/415VAC 3-phase 4-wire
Voltage Range Default value is -20%~+15%; -40%, -30%, -10% ~ +10%, +15% , other ranges can be set via software
Overload Capacity

Long term at 135% rated load ,150%<load<180% more than 10 min,
load>1000% 100ms

Output
Inverter Output Voltage 380/400/415VAC 3-phase 4-wire
Voltage Accuracy ±0.5% ( balanced load ) , ±1% ( unbalanced load )
THDV THDV<1% (linear load) , THDV<3% (nonlinear load)
Power Factor 0.9
Three Phase Angle Accuracy 120°± 0.5°
Current Crest Ratio 3:1
Overload Capacity 110%1h,125%10mins,150%1mins,>150%200ms
Transfer Time 0ms,15ms (Eco Mode)
System
Frequency 50Hz/60Hz (Settable)
Mains Synchronization Range ±2Hz(Default value), adjustable with step of 0.5Hz within range of +/- 0.5Hz - 3Hz
Protection Level IP20
Communication Ports RS232,RS485,dry contact, SNMP card, EPO, generator port
System efficiency >96% at load above 50%, >95% at load above 25%
Operation Temperature 0-40ºC
Storage Temperature -25ºC~70ºC ( without battery)
Humidity 0-95% (no-condensing)
Noise(dB) 55-62dB,Adjusted with load
Weight module:PM20 20KVA power module : 35KG
module:PM30 30KVA power module : 35KG
module:PM40 40KVA power module : 35KG
Dimension (W x D x H)mm 3 module cabinet 600X900X1135
5 module cabinet(5 battery cabinet option) 600X1100X2070/
6 module cabinet 600X900X1535
10 module cabinet 900X900X2080
power module 440X650X132(3U)(10KVA/20KVA/30KVA)


(Optional South America 208V must be derating use)
 
FAQ:
 
Q: Could you do custom-made products?
A: Yes, please show us the drawing of the goods you need, or your requirement for the products, customized UPS is available.
 
Q: Can you print my picture or logo onto the products?
A: Yes, OEM and ODM accepted
 
Q: What included in the products?
A: It includes UPS unit, user manual, 2% free spares together with shipment for urgent issue. Test certificate(optional)
 
Q: Nobody in our company know how to install the UPS?
A: We can despatch engineer to assist you solve the problem if necessary(But you are requested to pay for the cost of ticket, hotel etc. ). Or you can despatch engineer(s) to our company to get training.
 
CONSNANT Modular UPS in hospital
 

Three Phase High Capacity UPS System Parallel Redundancy Online 30 - 180KVA 0