Shenzhen Consnant Technology Co., Ltd. 86-755-29772322 sales@consnant.com
Three Phase Modular UPS System Parallel Redundancy Backup High Stability

Three Phase Modular UPS System Parallel Redundancy Backup High Stability

  • High Light

    redundant ups power supply

    ,

    commercial ups battery backup

  • Phase
    Three
  • Voltage
    380/400/415VAC
  • Frequency
    50HZ
  • Power Module
    30KVA
  • Battery Cabinet
    Hot-swap
  • Bypass
    Independent Bypass Of Each Power Module
  • Place of Origin
    China
  • Brand Name
    CONSNANT
  • Certification
    CE
  • Model Number
    CNM331
  • Minimum Order Quantity
    1 set
  • Packaging Details
    Wooden case
  • Payment Terms
    L/C, T/T, Western Union
  • Supply Ability
    200 sets per month

Three Phase Modular UPS System Parallel Redundancy Backup High Stability

 CNM331 Series 30-300KVA  Parallel Redundancy Online UPS
​The CNM331 series three phases input and three phases output UPS,adopted modular design and the N+X parallel redundant technology,the capacity from 20KVA to 300KVA. This series of UPS products can almost completely solve all the power problems such as power off, high voltage, low voltage, instantaneous voltage drop, reduce the oscillation, high voltage pulse, voltage fluctuations, surge voltage, harmonic distortion, clutter interference, frequency fluctuations etc. This product is suitable for a wide range of applications, for example: computer equipment, communication systems and automation equipment etc.
Digital control
All parts of the series architecture using digital control,the performance indicators of UPS are very good and the control system more reliable.
19 inch standard cabinet can perfectly match the application environment of data center
N+X parallel redundant of power module
The quantity of power module can set freely. When the power module more than 2 pieces use on parallel, the system availability reached 99.999%,the MTBF will be over 250,000 hours
Control system parallel redundant
Each power module uses an independent control system,the power module of UPS is controlled independently based on the information shared by each other. Suppose any power module fails, it can be disconnected from the parallel system immediately. It will not cause harm to the complete system.
Support to use on parallel, maximum 4 cabinets
Optimized distribution bus cabinet to ensure the safety when use on parallel
Separate bypass for each power module
Common use battery bank when several UPS power modules or UPS cabinet use on parallel
Intelligent battery management
Technical parameter:

Model90kVA 150kVA300kVA
CapacityUPS Cabinet

30~90KVA/
27~81KW

30~150KVA/
27~135KW

30~300KVA/
27~270KW

Power Module30KVA/27KW
InputInput type3 Phase, 4 Wires + Grounding
Rated Voltage380/400V/415VAC
Voltage Range208~478VAC
Frequency Range40~70Hz
Power Factor≥0.99
Bypass RangeBypass protection highest voltage:+15%(available to choose +5%,+10%,+25%)
Bypass protection lowest voltage:-45%(available to choose -20%,-30%)
Bypass protection frequency range:±10%
Input current harmonic≤3% (100% nonlinear load)
OutputOutput type3 Phase, 4 Wires + Grounding
Rated Voltage380/400V/415VAC
Power Factor0.9
Voltage accuracy±2%
Output FrequencyAC ModeSynchronize with the input;when the main power frequency over the range of ±10%(available to choose ±1%,±2%,±4%,±5%),output frequency will be 50×(±0.2)Hz
Battery Mode(50/60±0.2%)Hz
Load Crest Ratio3:01
Transfer timeAC to Bypass: 0ms(tracking);AC to Battery:0ms
Overload AbilityLoad ≤110%,60min,≤125%,continue working 10min,≤150% continue working 1min,≥150% off
Output voltage distortion≤2% linear load
≤5% non linear load
EfficiencyNormal Mode ≥92%
InterfaceUPS cabinetRS232,RS485,2 pieces Intelligent Slot,dry contact
BatteryBattery Voltage±192V±204V±216V±228V±240V DC; (32 pcs,34 pcs,36 pcs,38 pcs,40 pcs are optional)
Charge currentUPS Cabinet45Amax75Amax150Amax
Power Module15Amax
Working Environments Operation Temperature0℃~40℃
Humidity0~95% no-codensing
Storage Temperature-25℃~55℃
Altitude< 1500m
Physical characteristics

Body Size
W×D×H

UPS cabinet600*840*1400600*840*1400600*1100*2000
(mm)Power Module443*580*131
WeightUPS cabinet157169306
(Kg)Power Module33
StandardCE,EN/IEC 62040-2,EN/IEC 62040-1-1,YD/T1095-2008

Three Phase Modular UPS System Parallel Redundancy Backup High Stability 0