Send Message
Shenzhen Consnant Technology Co., Ltd. 86-755-29772322 sales@consnant.com
Single Phase Off Grid Inverter Application in Hospital,factory,hotel,school

Single Phase Off Grid Inverter Application in Hospital,factory,hotel,school

  • High Light

    gridgrid hybrid solar power inverter

    ,

    solar panel dc to ac inverter

  • Rated Power (W)
    10KW-50KW
  • Generator
    10-50KW
  • Battery Voltage
    240VDC
  • Max . AC Charging Current
    40-200A
  • Maximum Battery Current
    42-210A
  • AC Charge Voltage
    250-290VDC
  • Phase
    1Phase 2Wire + PE
  • Frequency
    50 / 60 Hz ± 3 %
  • AC Output Voltage
    L - N : 220 / 230 / 240 Vac 1Phase 2Wire + PE
  • Overload Capability
    > 125 % Load For 10 Min , 150 % Load For 30sec ,> 150 % Load For 10sec , 200 % Load At 2sec
  • Efficiency
    > 90 %
  • Protection
    Over Current , Overload , Over Temperature , Short Circuit , Over Voltage , Under Voltage , Low Battery And Over Battery Voltage
  • Protection Degree
    IP20
  • Dimension WxDxH ( Mm .)
    800*1030*1655 (with Built-in MPPT)
  • Weight(kg)
    200-600
  • Place of Origin
    Shenzhen, China
  • Brand Name
    CONSNANT
  • Certification
    ICE, ISO
  • Model Number
    CNS 115
  • Minimum Order Quantity
    2 pieces
  • Price
    Negotiable
  • Packaging Details
    Export Standard Package
  • Delivery Time
    5-8 days for sample order, 15-21 days for large quantity
  • Payment Terms
    T/T, L/C
  • Supply Ability
    1000 pieces per month

Single Phase Off Grid Inverter Application in Hospital,factory,hotel,school

Single Phase Off Grid Inverter Application in Hospital,factory,hotel,school

 

 

Application field:

 

 Hospital

 Factory

 Hotel

 School

 

Key Features:

  • Single phase inverter technology with output transformer
  • Include PWM with MPPT charge controller
  • Provide uninterruptible backup power to load when utility grid line is not available
  • High efficiency > 90%
  • Generator connected signal and automatic start generator signal when generator as other energy source of the system
  • Transfer time 4-10ms inverter to utility
  • Special design for using at high grid fluctuation area
  • ISO9001 and ISO14001 certified factory
  1.  
  •  

 

Technical Specifications:

Model CNS115-10 CNS115-15 CNS115-20 CNS115-25 CNS115-30 CNS115-40 CNS115-50
INVERTER Power 10kw 15kw 20kw 25kw 30kw 40kw 50kw
Battery Storage 100 - 200Ah 150 - 300Ah 200 - 400Ah 250 - 500Ah 300 - 600Ah 350 - 750Ah 450 - 900Ah
PV System 10 - 12kwp 15 - 17kwp 20 - 25kwp 25 - 30kwp 30 - 35kwp 35 - 40kwp 45 - 50kwp
Generator 10kw 15kw 20kw 25kw 30kw 40kw 50kw
Electrical Grid 10kw / 45A 15kw / 68A 20kw / 90A 25kw / 115A 30kw / 136A 40kw / 160A 50kw / 227A
MPPT Solar Controller 240VDC 50A 70A 100A 100A 150A 180A 200A
BATTERY VOLTAGE Normal Voltage 240 Vdc
Voltage Range 210 - 290 Vdc
Max . AC Charging Current 40A 60A 75A 90A 112A 130A 200A
Maximum Battery current 42A 63A 85A 105A 125A 145A 210A
AC CHARGE Voltage Charge 250 - 290 Vdc
Charging Current ( Max .) 20Adc 30Adc 40Adc 50Adc 60Adc 75Adc 100Adc
AC INPUT GRID LINE Generator Power 10kw 15kw 20kw none none none none
  Voltage L - N : 220 / 230 / 240 Vac +/ - 10 %
GENERATOR Phase 1Phase 2Wire + PE
  Frequency 50 / 60 Hz ± 3 %
  Function start / stop Relay dry contact 10A ( ACC on and start )
  Power Continuous ( PF = 1 ) 10kw 15kw 20kw 25kw 30kw 40kw 50kw
AC OUTPUT Output Voltage L - N : 220 / 230 / 240 Vac 1Phase 2Wire + PE
Voltage Regulation +/ - 5 % steady load .< 4 % step load within 0 . 1sec
Frequency 50 / 60 Hz ± 0 . 1 %
Total Harmonic Distortion THD < 3 % ( linear load )
Wave Form Pure sine wave
Overload Capability > 125 % load for 10 min , 150 % load for 30sec ,> 150 % load for 10sec , 200 % load at 2sec
ISOLATION Type Galvanic isolation
EFFICIENCY Ivnerter Peak ( Max .) > 90 %
PROTECTION System Over current , Overload , Over temperature , Short circuit , Over voltage , Under voltage , Low battery and Over battery voltage
IP level IP20
ALARM Operation Alarm Low battery , Overload , Over temperature and Fault
COOLING System Operate Temperature control
ENVIRONMENT Tenmperature 0 - 45 ℃
Relative Humidity 0 - 95 %( Non - condensing )
DESIGN REGULATION Tested According to AS / NZ 3100 , EN61000 - 6 - 1 / - 3 , EN50178 and IEC 62040
  Dimension WxDxH ( mm .) 800*1030*1655 (with built-in MPPT)
PHYSICAL Weight ( kg ) 200 250 250 250 300 550 600

 

  Single Phase Off Grid Inverter Application in Hospital,factory,hotel,school 0

 

Our packing

Single Phase Off Grid Inverter Application in Hospital,factory,hotel,school 1

Single Phase Off Grid Inverter Application in Hospital,factory,hotel,school 2

 

Certification

Single Phase Off Grid Inverter Application in Hospital,factory,hotel,school 3