Shenzhen Consnant Technology Co., Ltd. 86-755-29772322 sales@consnant.com
Off Line UPS Uninterrupted Power Supply for Personal Computer

Off Line UPS Uninterrupted Power Supply for Personal Computer

  • High Light

    uninterruptible power systems

    ,

    ups pc power supply

  • Modle
    500VA-1200VA
  • Input Voltage
    220VAC
  • Input Frequency
    50Hz
  • Cooling
    Natural
  • Appear
    LED/LCD
  • Safety
    GB 4943.1-2011
  • Place of Origin
    Shenzhen, China
  • Brand Name
    CONSNANT
  • Certification
    ICE, ISO
  • Model Number
    HK
  • Minimum Order Quantity
    100 pieces
  • Price
    Negotiable
  • Packaging Details
    Export standard package
  • Delivery Time
    15-21 days against deposit
  • Payment Terms
    T/T, L/C
  • Supply Ability
    2000 pieces per month

Off Line UPS Uninterrupted Power Supply for Personal Computer

Technical specification
Model 500VA 800VA 1000VA 1200VA  
Input 220Vac 50Hz, 3.6A Max 220Vac 50Hz, 5.7A Max 220Vac 50Hz, 7.1A Max 220Vac 50Hz, 8.5A Max  
Output power 220Vac 50Hz, 2.3A Max 220Vac 50Hz, 3.6A Max 220Vac 50Hz, 4.5A Max 220Vac 50Hz, 5.4A Max  
Capacity 500VA/300W 800VA/480W 1000VA/600W 1200VA/720W  
Input electrical features
Rated voltage 220Vac  
Utility voltage range (140~290)±5Vac  
The low loss voltage of utility 140V ±5V  
The low loss back voltage of utility 150V ±5V  
The second boost voltage of utility 178V ±5V  
The second boost back voltage of utility 172V±5V  
The first boost voltage of utility 202V±5V  
The first boost back voltage of utility 197V±5V  
The buck voltage of utility 250V±5V  
The buck back voltage of utility 245V±5V  
The high loss voltage of utility 290V±5V  
The high loss back voltage of utility 280V±5V  
Input power factor 0.98 220VAC,full R load
Input frequency 50/60Hz Auto select

Autoselect

(Input frequency)

The nominal frequence is configured according to measured input frequence during the unit starting.  
If measured frequence is > 55Hz, nominal frequence setting will be 60Hz  
If measured frequence is ≤ 55Hz, nominal frequence setting will be 50Hz  
Mains frequency range (40~70)±1Hz  
Generator Support generator input Generator rating≥2*UPS rating
Input current(Max) 3.6A Max 5.7A Max 7.1A Max 8.1A Max  
Auto restart Support When the mains recovers if the UPS is shutdown for battery low or remote shutdown
Output electrical features
Rated voltage 220Vac
Output voltagerange(Linemode) 220Vac±10%
Output voltage range(battery mode) 220Vac± 5%
Output capacity 500VA/ 300W 800VA/ 480W 1000VA/ 600W 1200VA/ 720W  
Output Power Factor 0.6  
Output current(Max) 2.3A Max 3.6A 4.5A Max 5.4A Max  
Output wave(Line mode) Sine wave  
Output wave(battery mode) Square wave  
Output frequency (Line mode) Synch with mains input  
Output frequency (battery mode) (50/60)±1Hz (Frequency self-adapt system)  
Transfer time ≤10ms

 

 

Overload protection

110% < Load ≤ 120%, buzzer beeps ; output shuts off in 5 mins, and buzzer beeps continuously.
Load > 120%, output shuts off, buzzer beeps continuously.
 
Short circuit (battery mode) Output shuts off, buzzer beeps continuously.  
Batteries features
  Sealed Lead-acid Batteries Maintenance of Free
Rated battery voltage 12VDC 12VDC 24VDC 24VDC  
Amount/Capacity 1PC/ 12V7AH 1PC/ 12V9AH 2PCS/ 12V7AH 2PCS/ 12V9AH  
Backup time > 6Mins (Half load)  
Low battery voltage ≤11V ≤22V  
Battery shutdown voltage 10V±0.5V 20V±0.5V  
Battery overvoltage protection 14.5V±0.5V 29V±0.5V  
Charger voltage 13.7V±0.5V 27.4V±0.5V  
Charging current 0.5A  
Shutdown automatically charge Yes  
Lights and alarms
Line mode, Battery replacement, Battery mode, Fault mode, Battery mode, Low battery voltage, Over load Green led flash when it was in the off-mode charging
Communication interface
Intelligent RS-232, Intelligent USB Optional
Monitoring software, line of communication Gaving together with machine
Communication interface  
RJ45, RJ11/12 Optional
Environment
Operating temperatures 0℃~40℃  
Altitude <1000M  
Noise ≤35dB (1m from front panel)  
Storage temperatures -15℃~45℃  
Relative humidity 0%~90%(No condensation water)  
Cooling Natural  
Appear
LED/LCD LED displays UPS status  
Standard
Safety GB 4943.1-2011  
Transportation
Drop test GB-T4857-18  
Vibration test B-WR1-129(GB-T14715-93)  
Machinery features
Size L×W×H(mm) 295x90x140 329X90X145 345x122x190  
Net weight (kg) 4.2 5.4 7.9 9