Send Message
Shenzhen Consnant Technology Co., Ltd. 86-755-29772322 sales@consnant.com
Hybrid Off Grid Solar Power Inverter 24V / 48V 1 - 12kw 50 / 60Hz Customized

Hybrid Off Grid Solar Power Inverter 24V / 48V 1 - 12kw 50 / 60Hz Customized

  • High Light

    solar power 3 phase inverter

    ,

    solar panel dc to ac inverter

  • Frequency
    50/60Hz
  • Display
    LED/LCD
  • Max.PV Open Circuit Array Voltage
    24V For 55Vdc / 48V For 110Vdc
  • Indicators
    LED+LCD Display
  • Operating Temperature Range
    0ºC To 40ºC
  • Storage Temperature
    15ºC~60ºC
  • Audible Noise
    60dB Max
  • Cooling
    Forced Air,variable Speed Fan
  • Place of Origin
    Shenzhen, China
  • Brand Name
    CONSNANT
  • Certification
    CE, ISO9001, ISO14001
  • Model Number
    CNS110
  • Minimum Order Quantity
    10
  • Price
    Negotiable
  • Packaging Details
    Each unit in one carton
  • Delivery Time
    5-7 days for sample order, 7-15 days for mass production
  • Payment Terms
    T/T, L/C, Western Union
  • Supply Ability
    50000 pieces per year

Hybrid Off Grid Solar Power Inverter 24V / 48V 1 - 12kw 50 / 60Hz Customized

Hybrid Off Grid Solar Power Inverter 24V / 48V 1 - 12kw 50 / 60Hz Customized

 

 

Description:

 

CNS110 Series Hybrid Inverter is designed to serve as a backup power supply for AC loads. The input power of CNS110 Series hybrid inverter comes from PV system and AC grid which not only supply power to AC loads but also charge the battery bank when the power from AC grid or AC generator is present(also known as Line Mode).

In the event of the AC grid (or AC generator) outage, the AC loads can be alternatively powered by PV system(if the illumination is sufficient) and the battery bank.

 

 

Features:

 

1. AC/Solar Charging Off Grid Hybrid Inverter.

2. LED/LCD display, Enhanced functions setting via LCD, Man-machine intelligent design

3. Built-in 40A/60A optional MPPT solar charger controller.

4. LCD shows the solar capacity.

5. 5 stages adjustable AC charging current. AC charging also can be closed

6. AC/DC priority modes can be set.

7. Generator restart signal. (Dry contact)

8. 3 times peak power. Strong loading capacity.

9. Overload, output short-circuit protection.

 

 

 

System parameter :

 

Over-load Protection: 110%<load<150%, beeps 0.5s every 1s, and fault after 60s off the output,

                                   Load>150%, beeps 0.5s every 1s, and fault after 20s.
Surge rating(10s): 1:3(VA)
Power Saver: Load≦25W(enabled on “P/S auto” setting of Remote comtro;)
Protections:   Low battery, over charging, overload, over temp
Indicatoers:   LED+LCD Display

 

 


CNS110 Series Technical Specifications:

 

 

Model CNS110 1KW-12KW
Line Mode Specification: LV Model(1-6KW) HV Model(1-12KW)
Input Voltage Input Voltage Waveform Sinusoidal(utility or generator)
Nominal Input Voltage LV 12Vac HV 230Vac
Low Line Disconnect Normal:85Vac±4% Normal: 184 Vac±4%
Wide: 80 Vac±4% Wide: 135 Vac±4%
Low Line Reconnect Normal:95Vac±4% Normal:194Vac±4%
Wide: 85 Vac±4% Wide: 145Vac±4%
High Line Disconnect Normal:136Vac±4% Normal:263Vac±4%
Wide: 140 Vac±4% Wide: 263Vac±4%
High Line Reconnect Normal:131Vac±4% Normal:253Vac±4%
Wide: 135 Vac±4% Wide: 253 Vac±4%
Max AC Input Voltage 150V rms 270V rms
Input Frequency

Nominal Input

Frequency

50Hz/60Hz(Auto detection)
     

Low Line

Frequency Re-connect

51+0.3Hz for 60Hz;

41+0.3Hz for 50Hz;

Low Line

Frequency Disconnect

50+0.3Hz for 60Hz;

40+0.3Hz for 50Hz;

High Line

Frequency Reconnect

64+0.3Hz for 60Hz;

54+0.3Hz for 50Hz;

High Line

Frequency Disconnect

65+0.3Hz for 60Hz;

55+0.3Hz for 50Hz;

Main Function Output Voltage Waveform As same as input waveform
Over-load Protection(SMPS load) Air switch

Output Short

Circuit Protection

Air switch

Max Bypass

Overload Current

40A/50A

 

 

 

 

Battery Inverter Mode Specifications:
Output

Output Voltage

Waveform

Sine wave  

Rated Output

Power(KW)

LV:1-6KW HV:1KW-12KW
Power Factor 0.9~1.0  

Nominal Output

Voltage(V)

LV:120Vac±10% rms HV:230 Vac±10% rms

Nominal Output

Frequency(Hz)

60Hz±0.3Hz

50Hz±0.3Hz

     
DC Voltage

Nominal DC

Input Voltage

12VDC/24VDC/48VDC
DC Voltage Range 10-15.5Vdc for 12V battery
20-31.0 Vdc for 24V battery
40-62.0 Vdc for 48V battery
Low Battery Alarm 10.5Vdc±0.3Vdc for 12V Battery
21.0 Vdc±0.6Vdc for24V Battery
42.0 Vdc±1.2Vdc for 48V Battery

Low DC

input shut-down

10.0Vdc±0.3Vdc for 12V Battery
20.0Vdc±0.6Vdc for 24V Battery
40.0Vdc±1.2Vdc for 48V Battery
High DC input alarm&fault 16Vdc±0.3Vdc for 12V Battery
32Vdc±0.6Vdc for 24V Battery
64Vdc±1.2Vdc for 48V Battery
High DC input recorvery 15.5Vdc±0.3Vdc for 12V Battery
31.0Vdc±0.6Vdc for 24V Battery
62.0Vdc±1.2Vdc for 48V Battery
AC Charger Nominal Charge Current 20A/35A/50A/70A/90A(5satges adjustable charging current)
Charge Current Regulation ±5Adc
Over Charge protection Bat.V≧15.5VDC for 12V battery
Bat.V≧31.0VDC for 24V battery
Bat.V≧62.0VDC for48V battery
Beeps 0.5s every 1s& fault after 60S
Algorithm  
Three stage:Boost CC(Constant current stage) →Boost CV(Constant voltage stage) →Float(constant voltage stage)
Solar Charger Rated Charge Current 40A 60A
Rated Charge Battery Voltage Type 12V/24V/48V 12V/24V
Max PV open Circuit array voltage 12V for 40Vdc
24V for 40Vdc
48V for 110Vdc
Charger Mode MPPT
PV Low Voltage Re-connect PV≧Bat.V=3V
PV Low Voltage Disconnect PV≦Bat.V
Efficiency Efficiency ≧97%
Efficiency(Battery Mode) ≧85%
Efficiency(Line Mode) >98%
Transfer Time AC to DC 20ms(Max)
DC to AC 15ms(Max)
General Specifications Operation Temperature Range 0℃ to 40℃
Strorage Temperature -15℃~60℃
Operation Humidity 5% to 95%(non-condensing)
Audible Noise 60dB max
Cooling Forced air, Variable speed fan
Dimension(L*W*H)

1-3KW: 526*423*260mm

4-6KW:530*396*190mm

7-12KW:627*416*204mm

Net Weight(Kg) 1KW:21.5Kg; 1.5KW:23.5Kg
3KW:30.5Kg 4KW:32Kg
5KW:36.5Kg 6KW:40.5Kg
7KW:43.5Kg 8KW:50Kg
10KW:57.5Kg 12KW:60Kg

Hybrid Off Grid Solar Power Inverter 24V / 48V 1 - 12kw 50 / 60Hz Customized 0