Shenzhen Consnant Technology Co., Ltd. 86-755-29772322 sales@consnant.com
80KVA 64 KW Low Frequency Online UPS High Reliability Full Microprocessor Control

80KVA 64 KW Low Frequency Online UPS High Reliability Full Microprocessor Control

  • High Light

    three phase online ups

    ,

    server battery backup

  • Input Frequency Range
    45-65Hz
  • Input Voltage
    80-300VAC ±20% Three Phase
  • Soft Start
    0-100% In10"
  • Overload
    110% 125% 150% Of The Rated Current For 5h/10'/1'
  • Remote Signaling
    Volt Free Contacts
  • Remote Controls
    EPO And Bypass
  • Communication
    RS232 + Remote Contacts
  • Place of Origin
    Shenzhen, China
  • Brand Name
    CONSNANT
  • Certification
    CE, ISO9001, ISO14001
  • Model Number
    CNG310
  • Minimum Order Quantity
    1
  • Price
    Negotiable
  • Packaging Details
    Export Standard Package
  • Delivery Time
    15-20 days after receiving the 30% deposit
  • Payment Terms
    T/T, L/C, Western Union
  • Supply Ability
    2000 Pieces per year

80KVA 64 KW Low Frequency Online UPS High Reliability Full Microprocessor Control

 

CNG310 Series Low Frequency Online UPS 10-100KVA
 
 
 
Model:CNG310 10-100KVA(3Ph/1Ph)
Nominal Input Voltage: 380/400/415VAC
Output Power Factor:0.8
 
Technical parameter of CNG310 series:

Model powerCNG310 10KVA
10KVA15KVA20KVA30KVA40KVA60KVA80KVA100KVA
Capacity8KW12 KW16 KW24 KW32 KW48 KW64 KW80 KW
Input
Rated Voltage80-300 Vac three-phase
Voltage Range±20%
Frequency Range45-65Hz
Power Factor>0.92with harmonic filter
Current Harmonic Distortion<5%with harmonic filter
Soft Start0-100% in10"
Bypass Input
Rated Voltage230Vac single-phase
Permitted Voltage Range±15%(selectable from ±10% to ±25% from front panel)
Rated Frequency50/60Hz
Permitted Frequency Range±2%(selectable from ±1% to ±5% from front panel)
Standard FeaturesBackFeed protection; split bypass line
Batteries
TypeMaintenance-free lead-acid VRLA AGM / GEL;NICd
Battery Voltage384VDC
Maximum Recharge Current(A)0.2 X C10
AC Ripple Voltage<1%
Inverter Output
Number of Phases1
Rated Voltage(V)48Vac single-phase
Regulation of the Output Voltage48Vac phase/neutral(from control panel)
Crest Factor(Ipeak/Irms)3:1
Static Stability±1%
Dynamic Stability±5%
Frequency50/60Hz configurable
Overload110% 125% 150% of the rated current for 5h/10'/1'
Frequency Stability±0.05% on mains failure
Remote SignalingVolt free contacts
Remote ControlsEPO and Bypass
CommunicationRS232 + remote contacts
Operation Temperature0ºC/ + 40ºC
Relative Humidity<95% non condensing
ColorLight gray (RAL 7035)
Noise54dBA at 1m60dBA at 1m65dBA at 1m
Protection DegreeIP20
Efficiency Smart Modeup to 98%
ComplianceSafety:EN 62040-1-1(Directive 2006/95/EC); EMC:6200-2(Directive 2004/108/EC)
 

 
 
Application:
Servers,
Local area Network(LAN),
Data centers,
Telecommunications,
Electro-medical equipment
High intelligence and reliable power supply:
CNG310 provides maximum protection for vital mission-critical networks, security applications (electro- medical)and industrial applications thanks to its outstanding mechanical and electrical design.
The load is powered continuously by the inverter with a filtered, stabilized and regulated sine wave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges.
The CNG310 uses on-line double conversion technology (VFI) with isolation transformer on the inverter output.
The CNG310 is supplied with Watch & Save 3000 software as standard and can be remotely monitored
using the Power Net Guard system from anywhere in the world. Additional battery extension packs allow the standard battery run time to be extended up to several hours.
Minimum impact on suppliers easy source:
Input current distortion <4% for the CNG310 with filter with sinusoidal absorption to remove the risk of resonance with other input supply users or phase shift capacitor sets. The absorbed current distortion is independent of input supply parameters such as impedance. This enable CNG310 to deliver maximum performance levels regardless of the installation environment. With these input features CNG310 can achieve significant savings in terms of sizing and power supply courcesiso-ation transformers and generators over less sophisticated power systems.
Maximum battery care:
Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.
High reliability:
Extremely high short-circuit current to ensure compatibility with the most difficult transformer applications (lighting,drives and industrial processes) and an isolation transformer on the inverter output;
Full microprocessor control with no-break static and manual bypasses;
IGBT technology.
Other characteristics:
0.8 power factor make CNG310 suitable for powering ICT and Industrial loads;
High level diagnostics: event log with 128 messages, states,measurements and alarms - available from the built-in LCD with several languages;

  1. Back feed protection
  2. Maximum reliability and availability
  3. Low consumption level
  4. Advance communication
  5. Expandability:


80KVA 64 KW Low Frequency Online UPS High Reliability Full Microprocessor Control 0